Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • SCHNEIDER

Technical specifications

Concurrently switching neutral conductorNo
Connectable conductor cross section multi-wired0.75 - 4mm²
Rated current10A
Explosion-proofNo
Current limiting class3
Release characteristicOther
Frequency50 - 60Hz
Rated voltage415V
Over voltage category3
Voltage typeAC
Width in number of modular spacings2
Built-in depth78mm
Ambient temperature during operating-20 - 60°C
Additional equipment possibleNo
Rated insulation voltage Ui415V
Degree of protection (IP)IP20
Number of protected poles2
Connectable conductor cross section solid-core0.75 - 6mm²
Flush-mounted installationNo
Pollution degree2
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V-kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V-kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V1.5kA
Number of poles (total)2
Rated impulse withstand voltage Uimp4kV
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V1.5kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

GB2DB16 | Min. Prekidac TeSys_GB2 2P 10A Id=138A

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • SCHNEIDER

Technical specifications

Concurrently switching neutral conductor

Connectable conductor cross section multi-wired

0.75 .. 4mm²

Rated current

10A

Explosion-proof

Current limiting class

3

Release characteristic

Other

Frequency

50 .. 60Hz

Rated voltage

415V

Over voltage category

3

Voltage type

AC

Width in number of modular spacings

2

Built-in depth

78mm

Ambient temperature during operating

-20 .. 60°C

Additional equipment possible

Rated insulation voltage Ui

415V

Degree of protection (IP)

IP20

Number of protected poles

2

Connectable conductor cross section solid-core

0.75 .. 6mm²

Flush-mounted installation

Pollution degree

2

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

1.5kA

Number of poles (total)

2

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

1.5kA