Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • SCHNEIDER

Technical specifications

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V-kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V-kA
Release characteristicOther
Number of poles (total)2
Built-in depth78mm
Number of protected poles2
Rated voltage415V
Rated current12A
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V1.5kA
Flush-mounted installationNo
Concurrently switching neutral conductorNo
Over voltage category3
Additional equipment possibleNo
Degree of protection (IP)IP20
Width in number of modular spacings2
Rated insulation voltage Ui415V
Explosion-proofNo
Connectable conductor cross section multi-wired0.75 - 4mm²
Voltage typeAC
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V1.5kA
Pollution degree2
Rated impulse withstand voltage Uimp4kV
Frequency50 - 60Hz
Connectable conductor cross section solid-core0.75 - 6mm²
Current limiting class3
Ambient temperature during operating-20 - 60°C
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

GB2DB20

Main Product Image

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • SCHNEIDER

Technical specifications

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Release characteristic

Other

Number of poles (total)

2

Built-in depth

78mm

Number of protected poles

2

Rated voltage

415V

Rated current

12A

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

1.5kA

Flush-mounted installation

Concurrently switching neutral conductor

Over voltage category

3

Additional equipment possible

Degree of protection (IP)

IP20

Width in number of modular spacings

2

Rated insulation voltage Ui

415V

Explosion-proof

Connectable conductor cross section multi-wired

0.75 .. 4mm²

Voltage type

AC

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

1.5kA

Pollution degree

2

Rated impulse withstand voltage Uimp

4kV

Frequency

50 .. 60Hz

Connectable conductor cross section solid-core

0.75 .. 6mm²

Current limiting class

3

Ambient temperature during operating

-20 .. 60°C

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.