Technical specifications

Degree of protection (IP)IP20
Number of auxiliary contacts as normally closed contact1
Number of auxiliary contacts as normally open contact1
Overload release current setting1.63 - 2.5A
Type of electrical connection of main circuitScrew connection
Rated control supply voltage Us at DC24 - 24V
Rated control supply voltage Us at AC 60HZ- - -V
Rated control supply voltage Us at AC 50HZ- - -V
Rated operation power at AC-3, 400 V0.75kW
Voltage type for actuatingDC
Supporting protocol for SERCOSNo
Supporting protocol for INTERBUS-SafetyNo
Supporting protocol for AS-Interface Safety at WorkNo
Supporting protocol for ModbusNo
Supporting protocol for Foundation FieldbusNo
Supporting protocol for SUCONETNo
Supporting protocol for DeviceNet SafetyNo
Supporting protocol for DeviceNetNo
Supporting protocol for EtherNet/IPNo
Supporting protocol for PROFINET CBANo
Supporting protocol for PROFIsafeNo
Supporting protocol for SafetyBUS pNo
Supporting protocol for TCP/IPNo
Supporting protocol for CANNo
Supporting protocol for PROFIBUSNo
Supporting protocol for Data-HighwayNo
Supporting protocol for INTERBUSNo
Supporting protocol for other bus systemsNo
Supporting protocol for LONNo
Supporting protocol for PROFINET IONo
Supporting protocol for ASINo
Rail mounting possibleYes
Release classCLASS 10
Rated operation current Ie2.5A
Rated power, 460 V, 60 Hz, 3-phase-kW
Rated operation power at AC-3, 230 V, 3-phase-kW
With short-circuit releaseYes
Rated power, 575 V, 60 Hz, 3-phase-kW
Rated operation current at AC-3, 400 V2.5A
Rated conditional short-circuit current, type 2, 400 V130000A
Ambient temperature, upper operating limit60°C
Rated conditional short-circuit current, type 1, 480 Y/277 V-A
Rated conditional short-circuit current, type 1, 600 Y/347 V-A
Rated conditional short-circuit current, type 2, 230 V-A
Type of motor starterDirect online starter (DOL)
Temperature compensated overload protectionYes
Type of electrical connection for auxiliary- and control current circuitScrew connection
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

GV2DM107BD

Main Product Image

Details

  • Low-voltage industrial components
  • Motor starter/Motor starter combination
  • 1 KOM
  • SCHNEIDER

Technical specifications

Degree of protection (IP)

IP20

Number of auxiliary contacts as normally closed contact

1

Number of auxiliary contacts as normally open contact

1

Overload release current setting

1.63 .. 2.5A

Type of electrical connection of main circuit

Screw connection

Rated control supply voltage Us at DC

24 .. 24V

Rated control supply voltage Us at AC 60HZ

- .. -V

Rated control supply voltage Us at AC 50HZ

- .. -V

Rated operation power at AC-3, 400 V

0.75kW

Voltage type for actuating

DC

Supporting protocol for SERCOS

Supporting protocol for INTERBUS-Safety

Supporting protocol for AS-Interface Safety at Work

Supporting protocol for Modbus

Supporting protocol for Foundation Fieldbus

Supporting protocol for SUCONET

Supporting protocol for DeviceNet Safety

Supporting protocol for DeviceNet

Supporting protocol for EtherNet/IP

Supporting protocol for PROFINET CBA

Supporting protocol for PROFIsafe

Supporting protocol for SafetyBUS p

Supporting protocol for TCP/IP

Supporting protocol for CAN

Supporting protocol for PROFIBUS

Supporting protocol for Data-Highway

Supporting protocol for INTERBUS

Supporting protocol for other bus systems

Supporting protocol for LON

Supporting protocol for PROFINET IO

Supporting protocol for ASI

Rail mounting possible

Release class

CLASS 10

Rated operation current Ie

2.5A

Rated power, 460 V, 60 Hz, 3-phase

-kW

Rated operation power at AC-3, 230 V, 3-phase

-kW

With short-circuit release

Rated power, 575 V, 60 Hz, 3-phase

-kW

Rated operation current at AC-3, 400 V

2.5A

Rated conditional short-circuit current, type 2, 400 V

130000A

Ambient temperature, upper operating limit

60°C

Rated conditional short-circuit current, type 1, 480 Y/277 V

-A

Rated conditional short-circuit current, type 1, 600 Y/347 V

-A

Rated conditional short-circuit current, type 2, 230 V

-A

Type of motor starter

Direct online starter (DOL)

Temperature compensated overload protection

Type of electrical connection for auxiliary- and control current circuit

Screw connection