Number of auxiliary contacts as normally open contact1
Rated operation current Ie10A
Supporting protocol for CANNo
Supporting protocol for TCP/IPNo
Overload release current setting6 - 10A
Number of auxiliary contacts as normally closed contact1
Supporting protocol for ASINo
Supporting protocol for LONNo
Rated operation power at AC-3, 400 V4kW
Supporting protocol for PROFIBUSNo
Supporting protocol for SUCONETNo
Supporting protocol for DeviceNetNo
Supporting protocol for ModbusNo
Supporting protocol for INTERBUSNo
Type of electrical connection for auxiliary- and control current circuitScrew connection
Rated control supply voltage Us at DC- - -V
Supporting protocol for EtherNet/IPNo
Supporting protocol for PROFINET CBANo
Supporting protocol for Data-HighwayNo
With short-circuit releaseYes
Supporting protocol for other bus systemsNo
Supporting protocol for AS-Interface Safety at WorkNo
Supporting protocol for SafetyBUS pNo
Degree of protection (IP)IP20
Supporting protocol for PROFIsafeNo
Release classCLASS 10
Supporting protocol for SERCOSNo
Type of electrical connection of main circuitScrew connection
Rail mounting possibleYes
Supporting protocol for Foundation FieldbusNo
Rated control supply voltage Us at AC 50HZ24 - 24V
Supporting protocol for INTERBUS-SafetyNo
Rated control supply voltage Us at AC 60HZ24 - 24V
Supporting protocol for DeviceNet SafetyNo
Supporting protocol for PROFINET IONo
Ambient temperature, upper operating limit60°C
Rated conditional short-circuit current, type 2, 400 V130000A
Rated conditional short-circuit current, type 1, 600 Y/347 V-A
Rated conditional short-circuit current, type 2, 230 V-A
Rated operation current at AC-3, 400 V10A
Voltage type for actuatingAC
Rated operation power at AC-3, 230 V, 3-phase-kW
Rated conditional short-circuit current, type 1, 480 Y/277 V-A
Temperature compensated overload protectionYes
Rated power, 460 V, 60 Hz, 3-phase4kW
Rated power, 575 V, 60 Hz, 3-phase-kW
Type of motor starterDirect online starter (DOL)
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

Item is no longer available for sale!

GV2DM114B7

Main Product Image

Details

  • Low-voltage industrial components
  • Motor starter/Motor starter combination
  • 1 KOM
  • SCHNEIDER

Technical specifications

Number of auxiliary contacts as normally open contact

1

Rated operation current Ie

10A

Supporting protocol for CAN

Supporting protocol for TCP/IP

Overload release current setting

6 .. 10A

Number of auxiliary contacts as normally closed contact

1

Supporting protocol for ASI

Supporting protocol for LON

Rated operation power at AC-3, 400 V

4kW

Supporting protocol for PROFIBUS

Supporting protocol for SUCONET

Supporting protocol for DeviceNet

Supporting protocol for Modbus

Supporting protocol for INTERBUS

Type of electrical connection for auxiliary- and control current circuit

Screw connection

Rated control supply voltage Us at DC

- .. -V

Supporting protocol for EtherNet/IP

Supporting protocol for PROFINET CBA

Supporting protocol for Data-Highway

With short-circuit release

Supporting protocol for other bus systems

Supporting protocol for AS-Interface Safety at Work

Supporting protocol for SafetyBUS p

Degree of protection (IP)

IP20

Supporting protocol for PROFIsafe

Release class

CLASS 10

Supporting protocol for SERCOS

Type of electrical connection of main circuit

Screw connection

Rail mounting possible

Supporting protocol for Foundation Fieldbus

Rated control supply voltage Us at AC 50HZ

24 .. 24V

Supporting protocol for INTERBUS-Safety

Rated control supply voltage Us at AC 60HZ

24 .. 24V

Supporting protocol for DeviceNet Safety

Supporting protocol for PROFINET IO

Ambient temperature, upper operating limit

60°C

Rated conditional short-circuit current, type 2, 400 V

130000A

Rated conditional short-circuit current, type 1, 600 Y/347 V

-A

Rated conditional short-circuit current, type 2, 230 V

-A

Rated operation current at AC-3, 400 V

10A

Voltage type for actuating

AC

Rated operation power at AC-3, 230 V, 3-phase

-kW

Rated conditional short-circuit current, type 1, 480 Y/277 V

-A

Temperature compensated overload protection

Rated power, 460 V, 60 Hz, 3-phase

4kW

Rated power, 575 V, 60 Hz, 3-phase

-kW

Type of motor starter

Direct online starter (DOL)