Aleta.hr
Announcement

Registration is currently available to business customers only (B2B).

Details

  • •
  • •Low-voltage industrial components
  • •Motor starter/Motor starter combination
  • •Minimum order quantity: 1 pcs
  • •SCHNEIDER

Technical specifications

Height166mm
With transformerNo
Depth128.5mm
Number of command positions2
Number of auxiliary contacts as normally open contact0
Width88mm
Supporting protocol for LONNo
Number of indicator lights0
Supporting protocol for CANNo
Supporting protocol for TCP/IPNo
Rated control supply voltage Us at AC 60HZ230 - 230V
Supporting protocol for ModbusNo
Supporting protocol for other bus systemsNo
Supporting protocol for Data-HighwayNo
Supporting protocol for PROFIBUSNo
Rated control supply voltage Us at AC 50HZ230 - 230V
Supporting protocol for SUCONETNo
Number of auxiliary contacts as normally closed contact0
Supporting protocol for DeviceNetNo
Suitable for emergency stopNo
Supporting protocol for ASINo
Rail mounting possibleNo
External reset possibleYes
Supporting protocol for INTERBUS-SafetyNo
Supporting protocol for SERCOSNo
Supporting protocol for INTERBUSNo
Supporting protocol for AS-Interface Safety at WorkNo
Supporting protocol for DeviceNet SafetyNo
Type of electrical connection for auxiliary- and control current circuitScrew connection
Supporting protocol for PROFIsafeNo
Rated power, 575 V, 60 Hz, 3-phase5.5kW
Supporting protocol for PROFINET CBANo
Temperature compensated overload protectionNo
Rated power, 460 V, 60 Hz, 3-phase4kW
Rated conditional short-circuit current, type 2, 230 V-A
Rated operation power at AC-3, 230 V, 3-phase2.2kW
With fuseNo
Supporting protocol for SafetyBUS pNo
Voltage type for actuatingAC
Rated conditional short-circuit current, type 1, 480 Y/277 V-A
Ambient temperature, upper operating limit40°C
Supporting protocol for PROFINET IONo
With short-circuit releaseNo
Supporting protocol for EtherNet/IPNo
Supporting protocol for Foundation FieldbusNo
Rated conditional short-circuit current, type 1, 600 Y/347 V-A
Type of electrical connection of main circuitScrew connection
Rated conditional short-circuit current, type 2, 400 V-A
Rated operation power at AC-3, 400 V4kW
Rated operation current Ie9A
Overload release current setting- - -A
Degree of protection (IP)IP65
Rated control supply voltage Us at DC- - -V
Type of motor starterDirect online starter (DOL)
Rated operation current at AC-3, 400 V9A
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as