Aleta.hr
Announcement

Registration is currently available to business customers only (B2B).

Details

  • •
  • •Low-voltage industrial components
  • •Motor starter/Motor starter combination
  • •Minimum order quantity: 1 pcs
  • •SCHNEIDER

Technical specifications

Number of command positions1
Depth128.5mm
With transformerNo
Height166mm
Width88mm
Number of auxiliary contacts as normally open contact0
Suitable for emergency stopNo
Number of auxiliary contacts as normally closed contact0
Number of indicator lights0
Supporting protocol for INTERBUSNo
Supporting protocol for CANNo
Supporting protocol for LONNo
Supporting protocol for SUCONETNo
Supporting protocol for SERCOSNo
Supporting protocol for TCP/IPNo
Supporting protocol for PROFIBUSNo
Supporting protocol for Data-HighwayNo
Supporting protocol for ModbusNo
Rail mounting possibleNo
Supporting protocol for ASINo
Supporting protocol for INTERBUS-SafetyNo
Rated control supply voltage Us at AC 60HZ230 - 230V
Supporting protocol for other bus systemsNo
Supporting protocol for DeviceNetNo
Rated control supply voltage Us at AC 50HZ230 - 230V
External reset possibleNo
With short-circuit releaseNo
Type of electrical connection of main circuitScrew connection
Supporting protocol for AS-Interface Safety at WorkNo
With fuseNo
Type of electrical connection for auxiliary- and control current circuitScrew connection
Supporting protocol for PROFINET CBANo
Supporting protocol for PROFINET IONo
Supporting protocol for Foundation FieldbusNo
Supporting protocol for DeviceNet SafetyNo
Supporting protocol for EtherNet/IPNo
Temperature compensated overload protectionNo
Rated conditional short-circuit current, type 2, 230 V-A
Rated power, 575 V, 60 Hz, 3-phase7.5kW
Supporting protocol for SafetyBUS pNo
Voltage type for actuatingAC
Rated conditional short-circuit current, type 1, 480 Y/277 V-A
Rated conditional short-circuit current, type 1, 600 Y/347 V-A
Rated conditional short-circuit current, type 2, 400 V-A
Ambient temperature, upper operating limit40°C
Rated power, 460 V, 60 Hz, 3-phase5.5kW
Rated operation power at AC-3, 230 V, 3-phase3kW
Supporting protocol for PROFIsafeNo
Rated operation power at AC-3, 400 V5.5kW
Rated operation current Ie12A
Overload release current setting- - -A
Degree of protection (IP)IP65
Rated control supply voltage Us at DC- - -V
Type of motor starterDirect online starter (DOL)
Rated operation current at AC-3, 400 V12A
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as