Technical specifications

Rated control supply voltage Us at DC

- - -V

Overload release current setting

- - -A

Rated conditional short-circuit current, type 2, 400 V

-A

Rated conditional short-circuit current, type 1, 480 Y/277 V

-A

Rated conditional short-circuit current, type 1, 600 Y/347 V

-A

Rated conditional short-circuit current, type 2, 230 V

-A

Temperature compensated overload protection

No

Type of motor starter

Direct online starter (DOL)

With short-circuit release

No

Rated operation current at AC-3, 400 V

18A

Number of auxiliary contacts as normally open contact

0

Rated control supply voltage Us at AC 60HZ

230 - 230V

Voltage type for actuating

AC

Rated operation power at AC-3, 230 V, 3-phase

4kW

Number of auxiliary contacts as normally closed contact

0

Rated control supply voltage Us at AC 50HZ

230 - 230V

Rated operation power at AC-3, 400 V

7.5kW

Rated power, 575 V, 60 Hz, 3-phase

11kW

Rated power, 460 V, 60 Hz, 3-phase

7.5kW

Rated operation current Ie

18A

Type of electrical connection of main circuit

Screw connection

Type of electrical connection for auxiliary- and control current circuit

Screw connection

Rail mounting possible

No

With transformer

No

Number of command positions

2

Supporting protocol for TCP/IP

No

Supporting protocol for DeviceNet Safety

No

Degree of protection (IP)

IP65

Supporting protocol for SUCONET

No

Supporting protocol for ASI

No

Number of indicator lights

0

Supporting protocol for Data-Highway

No

Supporting protocol for INTERBUS-Safety

No

Supporting protocol for AS-Interface Safety at Work

No

Depth

153.5mm

Ambient temperature, upper operating limit

40°C

Width

101mm

Supporting protocol for LON

No

Supporting protocol for EtherNet/IP

No

Supporting protocol for PROFINET CBA

No

Supporting protocol for PROFIsafe

No

Supporting protocol for Foundation Fieldbus

No

Supporting protocol for other bus systems

No

Supporting protocol for SafetyBUS p

No

Suitable for emergency stop

No

Height

201mm

With fuse

No

Supporting protocol for PROFIBUS

No

External reset possible

Yes

Supporting protocol for CAN

No

Supporting protocol for INTERBUS

No

Supporting protocol for PROFINET IO

No

Supporting protocol for Modbus

No

Supporting protocol for DeviceNet

No

Supporting protocol for SERCOS

No


From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

LE1D18P7

Main Product Image

Details

  • Low-voltage industrial components
  • Motor starter/Motor starter combination
  • 1 KOM
  • SCHNEIDER

Technical specifications

Rated control supply voltage Us at DC

- .. -V

Overload release current setting

- .. -A

Rated conditional short-circuit current, type 2, 400 V

-A

Rated conditional short-circuit current, type 1, 480 Y/277 V

-A

Rated conditional short-circuit current, type 1, 600 Y/347 V

-A

Rated conditional short-circuit current, type 2, 230 V

-A

Temperature compensated overload protection

Type of motor starter

Direct online starter (DOL)

With short-circuit release

Rated operation current at AC-3, 400 V

18A

Number of auxiliary contacts as normally open contact

0

Rated control supply voltage Us at AC 60HZ

230 .. 230V

Voltage type for actuating

AC

Rated operation power at AC-3, 230 V, 3-phase

4kW

Number of auxiliary contacts as normally closed contact

0

Rated control supply voltage Us at AC 50HZ

230 .. 230V

Rated operation power at AC-3, 400 V

7.5kW

Rated power, 575 V, 60 Hz, 3-phase

11kW

Rated power, 460 V, 60 Hz, 3-phase

7.5kW

Rated operation current Ie

18A

Type of electrical connection of main circuit

Screw connection

Type of electrical connection for auxiliary- and control current circuit

Screw connection

Rail mounting possible

With transformer

Number of command positions

2

Supporting protocol for TCP/IP

Supporting protocol for DeviceNet Safety

Degree of protection (IP)

IP65

Supporting protocol for SUCONET

Supporting protocol for ASI

Number of indicator lights

0

Supporting protocol for Data-Highway

Supporting protocol for INTERBUS-Safety

Supporting protocol for AS-Interface Safety at Work

Depth

153.5mm

Ambient temperature, upper operating limit

40°C

Width

101mm

Supporting protocol for LON

Supporting protocol for EtherNet/IP

Supporting protocol for PROFINET CBA

Supporting protocol for PROFIsafe

Supporting protocol for Foundation Fieldbus

Supporting protocol for other bus systems

Supporting protocol for SafetyBUS p

Suitable for emergency stop

Height

201mm

With fuse

Supporting protocol for PROFIBUS

External reset possible

Supporting protocol for CAN

Supporting protocol for INTERBUS

Supporting protocol for PROFINET IO

Supporting protocol for Modbus

Supporting protocol for DeviceNet

Supporting protocol for SERCOS

From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.