Details
- Low-voltage industrial components
- Motor starter/Motor starter combination
- 1 KOM
- SCHNEIDER
Technical specifications
Rated control supply voltage Us at DC
- - -V
Overload release current setting
- - -A
Rated conditional short-circuit current, type 2, 400 V
-A
Rated conditional short-circuit current, type 1, 480 Y/277 V
-A
Rated conditional short-circuit current, type 1, 600 Y/347 V
-A
Rated conditional short-circuit current, type 2, 230 V
-A
Temperature compensated overload protection
No
Type of motor starter
Direct online starter (DOL)
With short-circuit release
No
Rated operation current at AC-3, 400 V
18A
Number of auxiliary contacts as normally open contact
0
Rated control supply voltage Us at AC 60HZ
230 - 230V
Voltage type for actuating
AC
Rated operation power at AC-3, 230 V, 3-phase
4kW
Number of auxiliary contacts as normally closed contact
0
Rated control supply voltage Us at AC 50HZ
230 - 230V
Rated operation power at AC-3, 400 V
7.5kW
Rated power, 575 V, 60 Hz, 3-phase
11kW
Rated power, 460 V, 60 Hz, 3-phase
7.5kW
Rated operation current Ie
18A
Type of electrical connection of main circuit
Screw connection
Type of electrical connection for auxiliary- and control current circuit
Screw connection
Rail mounting possible
No
With transformer
No
Number of command positions
2
Supporting protocol for TCP/IP
No
Supporting protocol for DeviceNet Safety
No
Degree of protection (IP)
IP65
Supporting protocol for SUCONET
No
Supporting protocol for ASI
No
Number of indicator lights
0
Supporting protocol for Data-Highway
No
Supporting protocol for INTERBUS-Safety
No
Supporting protocol for AS-Interface Safety at Work
No
Depth
153.5mm
Ambient temperature, upper operating limit
40°C
Width
101mm
Supporting protocol for LON
No
Supporting protocol for EtherNet/IP
No
Supporting protocol for PROFINET CBA
No
Supporting protocol for PROFIsafe
No
Supporting protocol for Foundation Fieldbus
No
Supporting protocol for other bus systems
No
Supporting protocol for SafetyBUS p
No
Suitable for emergency stop
No
Height
201mm
With fuse
No
Supporting protocol for PROFIBUS
No
External reset possible
Yes
Supporting protocol for CAN
No
Supporting protocol for INTERBUS
No
Supporting protocol for PROFINET IO
No
Supporting protocol for Modbus
No
Supporting protocol for DeviceNet
No
Supporting protocol for SERCOS
No
From same serie
LE1D18P7

Details
- Low-voltage industrial components
- Motor starter/Motor starter combination
- 1 KOM
- SCHNEIDER
Technical specifications
Rated control supply voltage Us at DC
- .. -V
Overload release current setting
- .. -A
Rated conditional short-circuit current, type 2, 400 V
-A
Rated conditional short-circuit current, type 1, 480 Y/277 V
-A
Rated conditional short-circuit current, type 1, 600 Y/347 V
-A
Rated conditional short-circuit current, type 2, 230 V
-A
Temperature compensated overload protection
Type of motor starter
Direct online starter (DOL)
With short-circuit release
Rated operation current at AC-3, 400 V
18A
Number of auxiliary contacts as normally open contact
0
Rated control supply voltage Us at AC 60HZ
230 .. 230V
Voltage type for actuating
AC
Rated operation power at AC-3, 230 V, 3-phase
4kW
Number of auxiliary contacts as normally closed contact
0
Rated control supply voltage Us at AC 50HZ
230 .. 230V
Rated operation power at AC-3, 400 V
7.5kW
Rated power, 575 V, 60 Hz, 3-phase
11kW
Rated power, 460 V, 60 Hz, 3-phase
7.5kW
Rated operation current Ie
18A
Type of electrical connection of main circuit
Screw connection
Type of electrical connection for auxiliary- and control current circuit
Screw connection
Rail mounting possible
With transformer
Number of command positions
2
Supporting protocol for TCP/IP
Supporting protocol for DeviceNet Safety
Degree of protection (IP)
IP65
Supporting protocol for SUCONET
Supporting protocol for ASI
Number of indicator lights
0
Supporting protocol for Data-Highway
Supporting protocol for INTERBUS-Safety
Supporting protocol for AS-Interface Safety at Work
Depth
153.5mm
Ambient temperature, upper operating limit
40°C
Width
101mm
Supporting protocol for LON
Supporting protocol for EtherNet/IP
Supporting protocol for PROFINET CBA
Supporting protocol for PROFIsafe
Supporting protocol for Foundation Fieldbus
Supporting protocol for other bus systems
Supporting protocol for SafetyBUS p
Suitable for emergency stop
Height
201mm
With fuse
Supporting protocol for PROFIBUS
External reset possible
Supporting protocol for CAN
Supporting protocol for INTERBUS
Supporting protocol for PROFINET IO
Supporting protocol for Modbus
Supporting protocol for DeviceNet
Supporting protocol for SERCOS
From same serie