Aleta.hr
Announcement

Registration is currently available to business customers only (B2B).

Details

  • •
  • •Low-voltage industrial components
  • •Motor starter/Motor starter combination
  • •Minimum order quantity: 1 pcs
  • •SCHNEIDER

Technical specifications

Width101mm
Depth153.5mm
Height201mm
With transformerNo
Number of command positions2
Suitable for emergency stopNo
Supporting protocol for ModbusNo
Number of auxiliary contacts as normally closed contact0
Supporting protocol for INTERBUSNo
Supporting protocol for LONNo
Number of auxiliary contacts as normally open contact0
Supporting protocol for PROFIBUSNo
Number of indicator lights0
Supporting protocol for TCP/IPNo
Supporting protocol for CANNo
Supporting protocol for ASINo
Supporting protocol for other bus systemsNo
Supporting protocol for Data-HighwayNo
Rated control supply voltage Us at AC 60HZ230 - 230V
Supporting protocol for AS-Interface Safety at WorkNo
Supporting protocol for DeviceNetNo
Supporting protocol for INTERBUS-SafetyNo
Rail mounting possibleNo
With short-circuit releaseNo
Type of electrical connection for auxiliary- and control current circuitScrew connection
Type of electrical connection of main circuitScrew connection
With fuseNo
External reset possibleYes
Supporting protocol for SERCOSNo
Supporting protocol for SUCONETNo
Rated control supply voltage Us at AC 50HZ230 - 230V
Supporting protocol for PROFINET CBANo
Supporting protocol for EtherNet/IPNo
Supporting protocol for DeviceNet SafetyNo
Supporting protocol for Foundation FieldbusNo
Supporting protocol for SafetyBUS pNo
Supporting protocol for PROFIsafeNo
Supporting protocol for PROFINET IONo
Voltage type for actuatingAC
Rated power, 460 V, 60 Hz, 3-phase7.5kW
Rated conditional short-circuit current, type 1, 480 Y/277 V-A
Temperature compensated overload protectionNo
Ambient temperature, upper operating limit40°C
Rated conditional short-circuit current, type 1, 600 Y/347 V-A
Rated power, 575 V, 60 Hz, 3-phase11kW
Rated operation power at AC-3, 230 V, 3-phase4kW
Rated conditional short-circuit current, type 2, 230 V-A
Rated conditional short-circuit current, type 2, 400 V-A
Rated operation power at AC-3, 400 V7.5kW
Rated operation current Ie18A
Overload release current setting- - -A
Degree of protection (IP)IP65
Rated control supply voltage Us at DC- - -V
Type of motor starterDirect online starter (DOL)
Rated operation current at AC-3, 400 V18A
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as