Aleta.hr

Details

  • Low-voltage industrial components
  • Motor starter/Motor starter combination
  • 1 KOM
  • SCHNEIDER

Technical specifications

Degree of protection (IP)IP65
Number of auxiliary contacts as normally closed contact0
Number of auxiliary contacts as normally open contact0
Type of electrical connection of main circuitScrew connection
Rated control supply voltage Us at DC0 - 0V
Overload release current setting1.8 - 2.6A
Rated control supply voltage Us at AC 60HZ220 - 220V
Rated control supply voltage Us at AC 50HZ220 - 220V
Voltage type for actuatingAC
Rated operation power at AC-3, 400 V1.1kW
Supporting protocol for SERCOSNo
Supporting protocol for INTERBUS-SafetyNo
Supporting protocol for AS-Interface Safety at WorkNo
Supporting protocol for Foundation FieldbusNo
Supporting protocol for ModbusNo
Supporting protocol for DeviceNet SafetyNo
Supporting protocol for DeviceNetNo
Supporting protocol for EtherNet/IPNo
Supporting protocol for PROFINET CBANo
Supporting protocol for PROFINET IONo
Supporting protocol for ASINo
Supporting protocol for TCP/IPNo
Supporting protocol for CANNo
Supporting protocol for PROFIBUSNo
Supporting protocol for Data-HighwayNo
Supporting protocol for other bus systemsNo
Supporting protocol for SUCONETNo
Supporting protocol for LONNo
Supporting protocol for PROFIsafeNo
Supporting protocol for SafetyBUS pNo
Supporting protocol for INTERBUSNo
Rail mounting possibleNo
Rated operation current Ie0A
Rated power, 460 V, 60 Hz, 3-phase0kW
Rated operation current at AC-3, 400 V2.6A
Rated power, 575 V, 60 Hz, 3-phase0kW
Rated operation power at AC-3, 230 V, 3-phase0.37kW
Ambient temperature, upper operating limit40°C
Rated conditional short-circuit current, type 2, 400 V0A
With short-circuit releaseNo
Rated conditional short-circuit current, type 1, 480 Y/277 V0A
Rated conditional short-circuit current, type 1, 600 Y/347 V0A
Type of motor starterDirect online starter (DOL)
Rated conditional short-circuit current, type 2, 230 V0A
Temperature compensated overload protectionNo
Type of electrical connection for auxiliary- and control current circuitScrew connection
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

LE1M35M708

Main Product Image

Details

  • Low-voltage industrial components
  • Motor starter/Motor starter combination
  • 1 KOM
  • SCHNEIDER

Technical specifications

Degree of protection (IP)

IP65

Number of auxiliary contacts as normally closed contact

0

Number of auxiliary contacts as normally open contact

0

Type of electrical connection of main circuit

Screw connection

Rated control supply voltage Us at DC

0 .. 0V

Overload release current setting

1.8 .. 2.6A

Rated control supply voltage Us at AC 60HZ

220 .. 220V

Rated control supply voltage Us at AC 50HZ

220 .. 220V

Voltage type for actuating

AC

Rated operation power at AC-3, 400 V

1.1kW

Supporting protocol for SERCOS

Supporting protocol for INTERBUS-Safety

Supporting protocol for AS-Interface Safety at Work

Supporting protocol for Foundation Fieldbus

Supporting protocol for Modbus

Supporting protocol for DeviceNet Safety

Supporting protocol for DeviceNet

Supporting protocol for EtherNet/IP

Supporting protocol for PROFINET CBA

Supporting protocol for PROFINET IO

Supporting protocol for ASI

Supporting protocol for TCP/IP

Supporting protocol for CAN

Supporting protocol for PROFIBUS

Supporting protocol for Data-Highway

Supporting protocol for other bus systems

Supporting protocol for SUCONET

Supporting protocol for LON

Supporting protocol for PROFIsafe

Supporting protocol for SafetyBUS p

Supporting protocol for INTERBUS

Rail mounting possible

Rated operation current Ie

0A

Rated power, 460 V, 60 Hz, 3-phase

0kW

Rated operation current at AC-3, 400 V

2.6A

Rated power, 575 V, 60 Hz, 3-phase

0kW

Rated operation power at AC-3, 230 V, 3-phase

0.37kW

Ambient temperature, upper operating limit

40°C

Rated conditional short-circuit current, type 2, 400 V

0A

With short-circuit release

Rated conditional short-circuit current, type 1, 480 Y/277 V

0A

Rated conditional short-circuit current, type 1, 600 Y/347 V

0A

Type of motor starter

Direct online starter (DOL)

Rated conditional short-circuit current, type 2, 230 V

0A

Temperature compensated overload protection

Type of electrical connection for auxiliary- and control current circuit

Screw connection

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.