Technical specifications
Number of auxiliary contacts as normally open contact
0
Rated operation power at AC-3, 400 V
2.2kW
Width
78mm
Height
160mm
Number of auxiliary contacts as normally closed contact
0
Number of command positions
2
Suitable for emergency stop
Depth
108mm
With transformer
Rated operation current Ie
5.5A
Overload release current setting
3.7 .. 5.5A
Number of indicator lights
1
Supporting protocol for LON
Supporting protocol for PROFIBUS
Supporting protocol for TCP/IP
Supporting protocol for CAN
Supporting protocol for ASI
Supporting protocol for SUCONET
Supporting protocol for Modbus
Supporting protocol for DeviceNet
Supporting protocol for Data-Highway
Supporting protocol for INTERBUS
Supporting protocol for other bus systems
Rated control supply voltage Us at AC 60HZ
220 .. 220V
Rail mounting possible
Rated control supply voltage Us at AC 50HZ
220 .. 220V
External reset possible
Rated control supply voltage Us at DC
- .. -V
Degree of protection (IP)
IP65
Type of electrical connection for auxiliary- and control current circuit
Screw connection
With fuse
Supporting protocol for SERCOS
With short-circuit release
Supporting protocol for AS-Interface Safety at Work
Supporting protocol for INTERBUS-Safety
Type of electrical connection of main circuit
Screw connection
Release class
CLASS 10 A
Supporting protocol for PROFIsafe
Rated power, 575 V, 60 Hz, 3-phase
3kW
Supporting protocol for EtherNet/IP
Rated power, 460 V, 60 Hz, 3-phase
2.2kW
Rated conditional short-circuit current, type 1, 480 Y/277 V
-A
Rated conditional short-circuit current, type 2, 230 V
-A
Supporting protocol for SafetyBUS p
Rated conditional short-circuit current, type 2, 400 V
-A
Supporting protocol for Foundation Fieldbus
Rated operation power at AC-3, 230 V, 3-phase
1.1kW
Rated operation current at AC-3, 400 V
5.5A
Supporting protocol for DeviceNet Safety
Rated conditional short-circuit current, type 1, 600 Y/347 V
-A
Voltage type for actuating
AC
Temperature compensated overload protection
Ambient temperature, upper operating limit
40°C
Supporting protocol for PROFINET CBA
Supporting protocol for PROFINET IO
Type of motor starter
Direct online starter (DOL)