Aleta.hr

Details

  • Low-voltage industrial components
  • Motor starter/Motor starter combination
  • 1 KOM
  • SCHNEIDER

Technical specifications

Number of auxiliary contacts as normally open contact0
Rated operation power at AC-3, 400 V2.2kW
Width78mm
Height160mm
Number of auxiliary contacts as normally closed contact0
Number of command positions2
Suitable for emergency stopNo
Depth108mm
With transformerNo
Rated operation current Ie5.5A
Overload release current setting3.7 - 5.5A
Number of indicator lights1
Supporting protocol for LONNo
Supporting protocol for PROFIBUSNo
Supporting protocol for TCP/IPNo
Supporting protocol for CANNo
Supporting protocol for ASINo
Supporting protocol for SUCONETNo
Supporting protocol for ModbusNo
Supporting protocol for DeviceNetNo
Supporting protocol for Data-HighwayNo
Supporting protocol for INTERBUSNo
Supporting protocol for other bus systemsNo
Rated control supply voltage Us at AC 60HZ220 - 220V
Rail mounting possibleNo
Rated control supply voltage Us at AC 50HZ220 - 220V
External reset possibleYes
Rated control supply voltage Us at DC- - -V
Degree of protection (IP)IP65
Type of electrical connection for auxiliary- and control current circuitScrew connection
With fuseNo
Supporting protocol for SERCOSNo
With short-circuit releaseNo
Supporting protocol for AS-Interface Safety at WorkNo
Supporting protocol for INTERBUS-SafetyNo
Type of electrical connection of main circuitScrew connection
Release classCLASS 10 A
Supporting protocol for PROFIsafeNo
Rated power, 575 V, 60 Hz, 3-phase3kW
Supporting protocol for EtherNet/IPNo
Rated power, 460 V, 60 Hz, 3-phase2.2kW
Rated conditional short-circuit current, type 1, 480 Y/277 V-A
Rated conditional short-circuit current, type 2, 230 V-A
Supporting protocol for SafetyBUS pNo
Rated conditional short-circuit current, type 2, 400 V-A
Supporting protocol for Foundation FieldbusNo
Rated operation power at AC-3, 230 V, 3-phase1.1kW
Rated operation current at AC-3, 400 V5.5A
Supporting protocol for DeviceNet SafetyNo
Rated conditional short-circuit current, type 1, 600 Y/347 V-A
Voltage type for actuatingAC
Temperature compensated overload protectionYes
Ambient temperature, upper operating limit40°C
Supporting protocol for PROFINET CBANo
Supporting protocol for PROFINET IONo
Type of motor starterDirect online starter (DOL)
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

LE1M35M712 | Pokretac Motorski 35A

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Motor starter/Motor starter combination
  • 1 KOM
  • SCHNEIDER

Technical specifications

Number of auxiliary contacts as normally open contact

0

Rated operation power at AC-3, 400 V

2.2kW

Width

78mm

Height

160mm

Number of auxiliary contacts as normally closed contact

0

Number of command positions

2

Suitable for emergency stop

Depth

108mm

With transformer

Rated operation current Ie

5.5A

Overload release current setting

3.7 .. 5.5A

Number of indicator lights

1

Supporting protocol for LON

Supporting protocol for PROFIBUS

Supporting protocol for TCP/IP

Supporting protocol for CAN

Supporting protocol for ASI

Supporting protocol for SUCONET

Supporting protocol for Modbus

Supporting protocol for DeviceNet

Supporting protocol for Data-Highway

Supporting protocol for INTERBUS

Supporting protocol for other bus systems

Rated control supply voltage Us at AC 60HZ

220 .. 220V

Rail mounting possible

Rated control supply voltage Us at AC 50HZ

220 .. 220V

External reset possible

Rated control supply voltage Us at DC

- .. -V

Degree of protection (IP)

IP65

Type of electrical connection for auxiliary- and control current circuit

Screw connection

With fuse

Supporting protocol for SERCOS

With short-circuit release

Supporting protocol for AS-Interface Safety at Work

Supporting protocol for INTERBUS-Safety

Type of electrical connection of main circuit

Screw connection

Release class

CLASS 10 A

Supporting protocol for PROFIsafe

Rated power, 575 V, 60 Hz, 3-phase

3kW

Supporting protocol for EtherNet/IP

Rated power, 460 V, 60 Hz, 3-phase

2.2kW

Rated conditional short-circuit current, type 1, 480 Y/277 V

-A

Rated conditional short-circuit current, type 2, 230 V

-A

Supporting protocol for SafetyBUS p

Rated conditional short-circuit current, type 2, 400 V

-A

Supporting protocol for Foundation Fieldbus

Rated operation power at AC-3, 230 V, 3-phase

1.1kW

Rated operation current at AC-3, 400 V

5.5A

Supporting protocol for DeviceNet Safety

Rated conditional short-circuit current, type 1, 600 Y/347 V

-A

Voltage type for actuating

AC

Temperature compensated overload protection

Ambient temperature, upper operating limit

40°C

Supporting protocol for PROFINET CBA

Supporting protocol for PROFINET IO

Type of motor starter

Direct online starter (DOL)

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.