  • Low-voltage switchgear and control gear (automation)
  • Motor starter/motor starter combination
  • 1 KOM
  • SCHNEIDER

Technical specifications

Rated control supply voltage Us at DC0 - 0V
Rated conditional short-circuit current, type 2, 400 V0A
Rated conditional short-circuit current, type 1, 480 Y/277 V0A
Rated conditional short-circuit current, type 1, 600 Y/347 V0A
Rated conditional short-circuit current, type 2, 230 V0A
Type of motor starterDirect online starter (DOL)
Rated power, 460 V, 60 Hz, 3-phase3kW
Rated control supply voltage Us at AC 60HZ220 - 220V
Rated operation current Ie8A
Rail mounting possibleNo
Number of auxiliary contacts as normally closed contact0
Number of command positions1
Rated operation power at AC-3, 400 V3kW
Rated power, 575 V, 60 Hz, 3-phase4kW
With transformerNo
Overload release current setting5.5 - 8A
Voltage type for actuatingAC
Temperature compensated overload protectionYes
Type of electrical connection for auxiliary- and control current circuitScrew connection
Number of auxiliary contacts as normally open contact0
Ambient temperature, upper operating limit40°C
Release classCLASS 10 A
Rated operation current at AC-3, 400 V8A
Rated operation power at AC-3, 230 V, 3-phase1.5kW
Rated control supply voltage Us at AC 50HZ220 - 220V
Type of electrical connection of main circuitScrew connection
Depth108mm
With short-circuit releaseNo
With fuseNo
External reset possibleNo
Degree of protection (IP)IP65
Supporting protocol for CANNo
Supporting protocol for DeviceNet SafetyNo
Supporting protocol for Data-HighwayNo
Supporting protocol for DeviceNetNo
Supporting protocol for ModbusNo
Supporting protocol for ASINo
Number of indicator lights0
Supporting protocol for EtherNet/IPNo
Supporting protocol for TCP/IPNo
Supporting protocol for Foundation FieldbusNo
Supporting protocol for PROFINET IONo
Supporting protocol for AS-Interface Safety at WorkNo
Supporting protocol for SUCONETNo
Supporting protocol for PROFIsafeNo
Supporting protocol for SafetyBUS pNo
Supporting protocol for INTERBUS-SafetyNo
Supporting protocol for SERCOSNo
Suitable for emergency stopNo
Supporting protocol for INTERBUSNo
Supporting protocol for PROFIBUSNo
Supporting protocol for LONNo
Supporting protocol for other bus systemsNo
Width78mm
Supporting protocol for PROFINET CBANo
Height160mm
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

LE1M35M714

Main Product Image

Details

  • Low-voltage switchgear and control gear (automation)
  • Motor starter/motor starter combination
  • 1 KOM
  • SCHNEIDER

Technical specifications

Rated control supply voltage Us at DC

0 .. 0V

Rated conditional short-circuit current, type 2, 400 V

0A

Rated conditional short-circuit current, type 1, 480 Y/277 V

0A

Rated conditional short-circuit current, type 1, 600 Y/347 V

0A

Rated conditional short-circuit current, type 2, 230 V

0A

Type of motor starter

Direct online starter (DOL)

Rated power, 460 V, 60 Hz, 3-phase

3kW

Rated control supply voltage Us at AC 60HZ

220 .. 220V

Rated operation current Ie

8A

Rail mounting possible

Number of auxiliary contacts as normally closed contact

0

Number of command positions

1

Rated operation power at AC-3, 400 V

3kW

Rated power, 575 V, 60 Hz, 3-phase

4kW

With transformer

Overload release current setting

5.5 .. 8A

Voltage type for actuating

AC

Temperature compensated overload protection

Type of electrical connection for auxiliary- and control current circuit

Screw connection

Number of auxiliary contacts as normally open contact

0

Ambient temperature, upper operating limit

40°C

Release class

CLASS 10 A

Rated operation current at AC-3, 400 V

8A

Rated operation power at AC-3, 230 V, 3-phase

1.5kW

Rated control supply voltage Us at AC 50HZ

220 .. 220V

Type of electrical connection of main circuit

Screw connection

Depth

108mm

With short-circuit release

With fuse

External reset possible

Degree of protection (IP)

IP65

Supporting protocol for CAN

Supporting protocol for DeviceNet Safety

Supporting protocol for Data-Highway

Supporting protocol for DeviceNet

Supporting protocol for Modbus

Supporting protocol for ASI

Number of indicator lights

0

Supporting protocol for EtherNet/IP

Supporting protocol for TCP/IP

Supporting protocol for Foundation Fieldbus

Supporting protocol for PROFINET IO

Supporting protocol for AS-Interface Safety at Work

Supporting protocol for SUCONET

Supporting protocol for PROFIsafe

Supporting protocol for SafetyBUS p

Supporting protocol for INTERBUS-Safety

Supporting protocol for SERCOS

Suitable for emergency stop

Supporting protocol for INTERBUS

Supporting protocol for PROFIBUS

Supporting protocol for LON

Supporting protocol for other bus systems

Width

78mm

Supporting protocol for PROFINET CBA

Height

160mm