Details
- •Low-voltage industrial components
- •Motor starter/Motor starter combination
- •1 KOM
- •SCHNEIDER
Technical specifications
LE1M35M716 | Pokretac Motorski 35A

Why Register?
- View wholesale prices with discounts
- Real-time stock availability
- Access invoices and dispatch notes
- Order history and frequently ordered items
- Exclusive B2B offers
and much more...
Details
- Low-voltage industrial components
- Motor starter/Motor starter combination
- 1 KOM
- SCHNEIDER
Technical specifications
With transformer
Rated operation power at AC-3, 400 V
4kW
Rated operation current Ie
11.5A
Depth
108mm
Number of auxiliary contacts as normally closed contact
0
Height
160mm
Number of command positions
2
Number of indicator lights
1
Width
78mm
Number of auxiliary contacts as normally open contact
0
Suitable for emergency stop
Supporting protocol for DeviceNet
Overload release current setting
8 .. 11.5A
Supporting protocol for SUCONET
Rated control supply voltage Us at AC 50HZ
220 .. 220V
Supporting protocol for Data-Highway
Supporting protocol for ASI
Supporting protocol for Modbus
Supporting protocol for other bus systems
External reset possible
Rail mounting possible
Supporting protocol for LON
Supporting protocol for INTERBUS
Rated control supply voltage Us at DC
- .. -V
Supporting protocol for CAN
Supporting protocol for PROFIBUS
Supporting protocol for TCP/IP
Rated control supply voltage Us at AC 60HZ
220 .. 220V
Type of electrical connection for auxiliary- and control current circuit
Screw connection
Supporting protocol for SERCOS
With fuse
Type of electrical connection of main circuit
Screw connection
Degree of protection (IP)
IP65
Supporting protocol for INTERBUS-Safety
With short-circuit release
Release class
CLASS 10 A
Supporting protocol for AS-Interface Safety at Work
Supporting protocol for PROFINET CBA
Supporting protocol for PROFINET IO
Supporting protocol for DeviceNet Safety
Supporting protocol for Foundation Fieldbus
Supporting protocol for EtherNet/IP
Supporting protocol for SafetyBUS p
Supporting protocol for PROFIsafe
Temperature compensated overload protection
Rated conditional short-circuit current, type 2, 400 V
-A
Rated operation current at AC-3, 400 V
11.5A
Voltage type for actuating
AC
Rated conditional short-circuit current, type 2, 230 V
-A
Rated conditional short-circuit current, type 1, 480 Y/277 V
-A
Ambient temperature, upper operating limit
40°C
Rated conditional short-circuit current, type 1, 600 Y/347 V
-A
Type of motor starter
Direct online starter (DOL)
Rated power, 460 V, 60 Hz, 3-phase
4kW
Rated power, 575 V, 60 Hz, 3-phase
-kW
Rated operation power at AC-3, 230 V, 3-phase
2.2kW