Aleta.hr
Announcement

Registration is currently available to business customers only (B2B).

Details

  • •
  • •Low-voltage industrial components
  • •Motor starter/Motor starter combination
  • •Minimum order quantity: 1 pcs
  • •SCHNEIDER

Technical specifications

Width78mm
Number of indicator lights1
Depth108mm
Supporting protocol for ASINo
Supporting protocol for PROFIBUSNo
Supporting protocol for SUCONETNo
Supporting protocol for DeviceNetNo
Supporting protocol for CANNo
Number of auxiliary contacts as normally closed contact0
Height160mm
Supporting protocol for LONNo
Supporting protocol for ModbusNo
Supporting protocol for Data-HighwayNo
Supporting protocol for TCP/IPNo
With transformerNo
Number of auxiliary contacts as normally open contact0
Number of command positions2
Suitable for emergency stopNo
Supporting protocol for INTERBUSNo
Rail mounting possibleNo
Supporting protocol for other bus systemsNo
External reset possibleYes
Supporting protocol for INTERBUS-SafetyNo
Rated control supply voltage Us at AC 60HZ230 - 230V
Supporting protocol for PROFIsafeNo
Release classCLASS 10 A
Supporting protocol for PROFINET CBANo
Supporting protocol for PROFINET IONo
Rated control supply voltage Us at AC 50HZ230 - 230V
Supporting protocol for AS-Interface Safety at WorkNo
Supporting protocol for SERCOSNo
Supporting protocol for EtherNet/IPNo
Type of electrical connection of main circuitScrew connection
With fuseNo
Supporting protocol for Foundation FieldbusNo
With short-circuit releaseNo
Supporting protocol for SafetyBUS pNo
Type of electrical connection for auxiliary- and control current circuitScrew connection
Supporting protocol for DeviceNet SafetyNo
Voltage type for actuatingAC
Rated power, 575 V, 60 Hz, 3-phase1.5kW
Rated operation power at AC-3, 230 V, 3-phase0.55kW
Rated power, 460 V, 60 Hz, 3-phase1.1kW
Rated conditional short-circuit current, type 1, 600 Y/347 V-A
Ambient temperature, upper operating limit40°C
Rated conditional short-circuit current, type 1, 480 Y/277 V-A
Rated conditional short-circuit current, type 2, 400 V-A
Temperature compensated overload protectionYes
Rated conditional short-circuit current, type 2, 230 V-A
Rated operation power at AC-3, 400 V1.5kW
Rated operation current Ie3.7A
Overload release current setting2.6 - 3.7A
Degree of protection (IP)IP65
Rated control supply voltage Us at DC- - -V
Type of motor starterDirect online starter (DOL)
Rated operation current at AC-3, 400 V3.7A
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as