Aleta.hr

Details

  • Low-voltage industrial components
  • Motor starter/Motor starter combination
  • 1 KOM
  • SCHNEIDER

Technical specifications

Width78mm
With transformerNo
Depth108mm
Number of command positions2
Height160mm
Number of auxiliary contacts as normally open contact0
Supporting protocol for DeviceNetNo
Supporting protocol for PROFIBUSNo
Rated control supply voltage Us at AC 60HZ230 - 230V
Supporting protocol for INTERBUSNo
Supporting protocol for SUCONETNo
Supporting protocol for other bus systemsNo
Supporting protocol for TCP/IPNo
Number of auxiliary contacts as normally closed contact0
Supporting protocol for LONNo
Supporting protocol for ModbusNo
External reset possibleYes
Supporting protocol for CANNo
Suitable for emergency stopNo
Supporting protocol for ASINo
Supporting protocol for Data-HighwayNo
Rail mounting possibleNo
Supporting protocol for SERCOSNo
Rated control supply voltage Us at AC 50HZ230 - 230V
Number of indicator lights1
Supporting protocol for INTERBUS-SafetyNo
Type of electrical connection for auxiliary- and control current circuitScrew connection
Type of electrical connection of main circuitScrew connection
Release classCLASS 10 A
Supporting protocol for EtherNet/IPNo
Supporting protocol for PROFINET IONo
Supporting protocol for PROFINET CBANo
Supporting protocol for SafetyBUS pNo
Voltage type for actuatingAC
Rated operation power at AC-3, 230 V, 3-phase1.5kW
Supporting protocol for AS-Interface Safety at WorkNo
With fuseNo
Temperature compensated overload protectionYes
Rated power, 460 V, 60 Hz, 3-phase3kW
Rated conditional short-circuit current, type 2, 400 V-A
Rated conditional short-circuit current, type 2, 230 V-A
With short-circuit releaseNo
Supporting protocol for Foundation FieldbusNo
Rated power, 575 V, 60 Hz, 3-phase4kW
Ambient temperature, upper operating limit40°C
Supporting protocol for PROFIsafeNo
Rated conditional short-circuit current, type 1, 480 Y/277 V-A
Rated conditional short-circuit current, type 1, 600 Y/347 V-A
Supporting protocol for DeviceNet SafetyNo
Rated operation power at AC-3, 400 V3kW
Rated operation current Ie8A
Overload release current setting5.5 - 8A
Degree of protection (IP)IP65
Rated control supply voltage Us at DC- - -V
Type of motor starterDirect online starter (DOL)
Rated operation current at AC-3, 400 V8A
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

LE1M35P714 | Pokretac Motorski 35A

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Motor starter/Motor starter combination
  • 1 KOM
  • SCHNEIDER

Technical specifications

Width

78mm

With transformer

Depth

108mm

Number of command positions

2

Height

160mm

Number of auxiliary contacts as normally open contact

0

Supporting protocol for DeviceNet

Supporting protocol for PROFIBUS

Rated control supply voltage Us at AC 60HZ

230 .. 230V

Supporting protocol for INTERBUS

Supporting protocol for SUCONET

Supporting protocol for other bus systems

Supporting protocol for TCP/IP

Number of auxiliary contacts as normally closed contact

0

Supporting protocol for LON

Supporting protocol for Modbus

External reset possible

Supporting protocol for CAN

Suitable for emergency stop

Supporting protocol for ASI

Supporting protocol for Data-Highway

Rail mounting possible

Supporting protocol for SERCOS

Rated control supply voltage Us at AC 50HZ

230 .. 230V

Number of indicator lights

1

Supporting protocol for INTERBUS-Safety

Type of electrical connection for auxiliary- and control current circuit

Screw connection

Type of electrical connection of main circuit

Screw connection

Release class

CLASS 10 A

Supporting protocol for EtherNet/IP

Supporting protocol for PROFINET IO

Supporting protocol for PROFINET CBA

Supporting protocol for SafetyBUS p

Voltage type for actuating

AC

Rated operation power at AC-3, 230 V, 3-phase

1.5kW

Supporting protocol for AS-Interface Safety at Work

With fuse

Temperature compensated overload protection

Rated power, 460 V, 60 Hz, 3-phase

3kW

Rated conditional short-circuit current, type 2, 400 V

-A

Rated conditional short-circuit current, type 2, 230 V

-A

With short-circuit release

Supporting protocol for Foundation Fieldbus

Rated power, 575 V, 60 Hz, 3-phase

4kW

Ambient temperature, upper operating limit

40°C

Supporting protocol for PROFIsafe

Rated conditional short-circuit current, type 1, 480 Y/277 V

-A

Rated conditional short-circuit current, type 1, 600 Y/347 V

-A

Supporting protocol for DeviceNet Safety

Rated operation power at AC-3, 400 V

3kW

Rated operation current Ie

8A

Overload release current setting

5.5 .. 8A

Degree of protection (IP)

IP65

Rated control supply voltage Us at DC

- .. -V

Type of motor starter

Direct online starter (DOL)

Rated operation current at AC-3, 400 V

8A

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.