Details
- •Low-voltage industrial components
- •Motor starter/Motor starter combination
- •1 KOM
- •SCHNEIDER
Technical specifications
LE1M35P714 | Pokretac Motorski 35A

Why Register?
- View wholesale prices with discounts
- Real-time stock availability
- Access invoices and dispatch notes
- Order history and frequently ordered items
- Exclusive B2B offers
and much more...
Details
- Low-voltage industrial components
- Motor starter/Motor starter combination
- 1 KOM
- SCHNEIDER
Technical specifications
Width
78mm
With transformer
Depth
108mm
Number of command positions
2
Rated operation power at AC-3, 400 V
3kW
Height
160mm
Number of auxiliary contacts as normally open contact
0
Rated operation current Ie
8A
Supporting protocol for DeviceNet
Supporting protocol for PROFIBUS
Rated control supply voltage Us at AC 60HZ
230 .. 230V
Supporting protocol for INTERBUS
Supporting protocol for SUCONET
Supporting protocol for other bus systems
Overload release current setting
5.5 .. 8A
Supporting protocol for TCP/IP
Number of auxiliary contacts as normally closed contact
0
Supporting protocol for LON
Supporting protocol for Modbus
External reset possible
Supporting protocol for CAN
Degree of protection (IP)
IP65
Suitable for emergency stop
Supporting protocol for ASI
Supporting protocol for Data-Highway
Rail mounting possible
Rated control supply voltage Us at DC
- .. -V
Supporting protocol for SERCOS
Rated control supply voltage Us at AC 50HZ
230 .. 230V
Number of indicator lights
1
Supporting protocol for INTERBUS-Safety
Type of electrical connection for auxiliary- and control current circuit
Screw connection
Type of electrical connection of main circuit
Screw connection
Release class
CLASS 10 A
Supporting protocol for EtherNet/IP
Supporting protocol for PROFINET IO
Supporting protocol for PROFINET CBA
Supporting protocol for SafetyBUS p
Voltage type for actuating
AC
Rated operation power at AC-3, 230 V, 3-phase
1.5kW
Supporting protocol for AS-Interface Safety at Work
With fuse
Type of motor starter
Direct online starter (DOL)
Temperature compensated overload protection
Rated power, 460 V, 60 Hz, 3-phase
3kW
Rated conditional short-circuit current, type 2, 400 V
-A
Rated conditional short-circuit current, type 2, 230 V
-A
With short-circuit release
Supporting protocol for Foundation Fieldbus
Rated operation current at AC-3, 400 V
8A
Rated power, 575 V, 60 Hz, 3-phase
4kW
Ambient temperature, upper operating limit
40°C
Supporting protocol for PROFIsafe
Rated conditional short-circuit current, type 1, 480 Y/277 V
-A
Rated conditional short-circuit current, type 1, 600 Y/347 V
-A
Supporting protocol for DeviceNet Safety