Details

  • •
  • •Low-voltage industrial components
  • •Motor starter/Motor starter combination
  • •Minimum order quantity: 1 pcs
  • •SCHNEIDER

Technical specifications

With transformerNo
Height160mm
Width78mm
Depth108mm
Suitable for emergency stopNo
Supporting protocol for PROFIBUSNo
Number of auxiliary contacts as normally closed contact0
Number of auxiliary contacts as normally open contact0
Number of command positions1
Supporting protocol for ASINo
Supporting protocol for TCP/IPNo
Number of indicator lights0
Supporting protocol for LONNo
Supporting protocol for ModbusNo
Supporting protocol for CANNo
Supporting protocol for INTERBUSNo
Supporting protocol for Data-HighwayNo
Supporting protocol for DeviceNetNo
Supporting protocol for SUCONETNo
External reset possibleNo
Rated control supply voltage Us at AC 50HZ380 - 380V
Supporting protocol for other bus systemsNo
Rated control supply voltage Us at AC 60HZ380 - 380V
Rail mounting possibleNo
With short-circuit releaseNo
Type of electrical connection of main circuitScrew connection
With fuseNo
Supporting protocol for SERCOSNo
Supporting protocol for Foundation FieldbusNo
Release classCLASS 10 A
Supporting protocol for INTERBUS-SafetyNo
Supporting protocol for PROFINET CBANo
Supporting protocol for DeviceNet SafetyNo
Type of electrical connection for auxiliary- and control current circuitScrew connection
Supporting protocol for AS-Interface Safety at WorkNo
Supporting protocol for EtherNet/IPNo
Supporting protocol for PROFIsafeNo
Supporting protocol for PROFINET IONo
Supporting protocol for SafetyBUS pNo
Rated conditional short-circuit current, type 2, 230 V-A
Temperature compensated overload protectionYes
Ambient temperature, upper operating limit40°C
Rated operation power at AC-3, 230 V, 3-phase0.37kW
Rated power, 460 V, 60 Hz, 3-phase0.75kW
Voltage type for actuatingAC
Rated conditional short-circuit current, type 1, 480 Y/277 V-A
Rated power, 575 V, 60 Hz, 3-phase1.1kW
Rated conditional short-circuit current, type 2, 400 V-A
Rated conditional short-circuit current, type 1, 600 Y/347 V-A
Rated operation power at AC-3, 400 V1.1kW
Rated operation current Ie2.6A
Overload release current setting1.8 - 2.6A
Degree of protection (IP)IP65
Rated control supply voltage Us at DC- - -V
Type of motor starterDirect online starter (DOL)
Rated operation current at AC-3, 400 V2.6A
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as