Aleta.hr

Details

  • Low-voltage industrial components
  • Motor starter/Motor starter combination
  • 1 KOM
  • SCHNEIDER

Technical specifications

Height160mm
Depth108mm
Width78mm
Number of auxiliary contacts as normally open contact0
Rated operation power at AC-3, 400 V1.5kW
With transformerNo
Number of command positions1
Overload release current setting2.6 - 3.7A
Number of auxiliary contacts as normally closed contact0
Rated operation current Ie3.7A
Suitable for emergency stopNo
Supporting protocol for TCP/IPNo
Supporting protocol for ASINo
Supporting protocol for LONNo
Number of indicator lights0
Supporting protocol for other bus systemsNo
Supporting protocol for SUCONETNo
Rated control supply voltage Us at AC 50HZ380 - 380V
Supporting protocol for INTERBUS-SafetyNo
Degree of protection (IP)IP65
Supporting protocol for CANNo
Rated control supply voltage Us at AC 60HZ380 - 380V
Rated control supply voltage Us at DC- - -V
Supporting protocol for DeviceNetNo
Supporting protocol for Data-HighwayNo
Supporting protocol for SERCOSNo
Supporting protocol for INTERBUSNo
Rail mounting possibleNo
Supporting protocol for ModbusNo
External reset possibleNo
With short-circuit releaseNo
With fuseNo
Supporting protocol for EtherNet/IPNo
Supporting protocol for DeviceNet SafetyNo
Release classCLASS 10 A
Supporting protocol for AS-Interface Safety at WorkNo
Supporting protocol for PROFIBUSNo
Type of electrical connection of main circuitScrew connection
Type of electrical connection for auxiliary- and control current circuitScrew connection
Supporting protocol for Foundation FieldbusNo
Supporting protocol for SafetyBUS pNo
Type of motor starterDirect online starter (DOL)
Rated operation current at AC-3, 400 V3.7A
Supporting protocol for PROFINET IONo
Rated operation power at AC-3, 230 V, 3-phase0.55kW
Ambient temperature, upper operating limit40°C
Rated conditional short-circuit current, type 2, 230 V-A
Rated conditional short-circuit current, type 1, 480 Y/277 V-A
Rated conditional short-circuit current, type 2, 400 V-A
Voltage type for actuatingAC
Rated conditional short-circuit current, type 1, 600 Y/347 V-A
Rated power, 575 V, 60 Hz, 3-phase1.5kW
Supporting protocol for PROFINET CBANo
Temperature compensated overload protectionYes
Supporting protocol for PROFIsafeNo
Rated power, 460 V, 60 Hz, 3-phase1.1kW
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

LE1M35Q710 | Pokretac Motorski 35A

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Motor starter/Motor starter combination
  • 1 KOM
  • SCHNEIDER

Technical specifications

Height

160mm

Depth

108mm

Width

78mm

Number of auxiliary contacts as normally open contact

0

Rated operation power at AC-3, 400 V

1.5kW

With transformer

Number of command positions

1

Overload release current setting

2.6 .. 3.7A

Number of auxiliary contacts as normally closed contact

0

Rated operation current Ie

3.7A

Suitable for emergency stop

Supporting protocol for TCP/IP

Supporting protocol for ASI

Supporting protocol for LON

Number of indicator lights

0

Supporting protocol for other bus systems

Supporting protocol for SUCONET

Rated control supply voltage Us at AC 50HZ

380 .. 380V

Supporting protocol for INTERBUS-Safety

Degree of protection (IP)

IP65

Supporting protocol for CAN

Rated control supply voltage Us at AC 60HZ

380 .. 380V

Rated control supply voltage Us at DC

- .. -V

Supporting protocol for DeviceNet

Supporting protocol for Data-Highway

Supporting protocol for SERCOS

Supporting protocol for INTERBUS

Rail mounting possible

Supporting protocol for Modbus

External reset possible

With short-circuit release

With fuse

Supporting protocol for EtherNet/IP

Supporting protocol for DeviceNet Safety

Release class

CLASS 10 A

Supporting protocol for AS-Interface Safety at Work

Supporting protocol for PROFIBUS

Type of electrical connection of main circuit

Screw connection

Type of electrical connection for auxiliary- and control current circuit

Screw connection

Supporting protocol for Foundation Fieldbus

Supporting protocol for SafetyBUS p

Type of motor starter

Direct online starter (DOL)

Rated operation current at AC-3, 400 V

3.7A

Supporting protocol for PROFINET IO

Rated operation power at AC-3, 230 V, 3-phase

0.55kW

Ambient temperature, upper operating limit

40°C

Rated conditional short-circuit current, type 2, 230 V

-A

Rated conditional short-circuit current, type 1, 480 Y/277 V

-A

Rated conditional short-circuit current, type 2, 400 V

-A

Voltage type for actuating

AC

Rated conditional short-circuit current, type 1, 600 Y/347 V

-A

Rated power, 575 V, 60 Hz, 3-phase

1.5kW

Supporting protocol for PROFINET CBA

Temperature compensated overload protection

Supporting protocol for PROFIsafe

Rated power, 460 V, 60 Hz, 3-phase

1.1kW