Aleta.hr

Details

  • Low-voltage industrial components
  • Motor starter/Motor starter combination
  • 1 KOM
  • SCHNEIDER

Technical specifications

With transformerNo
Number of indicator lights0
Width78mm
Suitable for emergency stopNo
Supporting protocol for TCP/IPNo
Number of command positions1
Overload release current setting3.7 - 5.5A
Height160mm
Number of auxiliary contacts as normally open contact0
Supporting protocol for ASINo
Rated operation power at AC-3, 400 V2.2kW
Supporting protocol for LONNo
Rated operation current Ie5.5A
Number of auxiliary contacts as normally closed contact0
Depth108mm
Supporting protocol for SUCONETNo
Supporting protocol for INTERBUSNo
Supporting protocol for CANNo
Supporting protocol for Data-HighwayNo
Supporting protocol for PROFIBUSNo
Supporting protocol for DeviceNetNo
Supporting protocol for ModbusNo
Rail mounting possibleNo
Type of electrical connection for auxiliary- and control current circuitScrew connection
With short-circuit releaseNo
Degree of protection (IP)IP65
Supporting protocol for SERCOSNo
Rated control supply voltage Us at DC- - -V
External reset possibleNo
Rated control supply voltage Us at AC 50HZ380 - 380V
Type of electrical connection of main circuitScrew connection
Rated control supply voltage Us at AC 60HZ380 - 380V
Supporting protocol for INTERBUS-SafetyNo
Release classCLASS 10 A
With fuseNo
Supporting protocol for other bus systemsNo
Supporting protocol for PROFINET IONo
Supporting protocol for DeviceNet SafetyNo
Voltage type for actuatingAC
Supporting protocol for PROFIsafeNo
Supporting protocol for EtherNet/IPNo
Rated operation power at AC-3, 230 V, 3-phase1.1kW
Supporting protocol for Foundation FieldbusNo
Supporting protocol for PROFINET CBANo
Type of motor starterDirect online starter (DOL)
Supporting protocol for SafetyBUS pNo
Supporting protocol for AS-Interface Safety at WorkNo
Rated conditional short-circuit current, type 2, 230 V-A
Temperature compensated overload protectionYes
Rated conditional short-circuit current, type 1, 600 Y/347 V-A
Rated conditional short-circuit current, type 2, 400 V-A
Ambient temperature, upper operating limit40°C
Rated power, 575 V, 60 Hz, 3-phase3kW
Rated operation current at AC-3, 400 V5.5A
Rated power, 460 V, 60 Hz, 3-phase2.2kW
Rated conditional short-circuit current, type 1, 480 Y/277 V-A
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

LE1M35Q712 | Pokretac Motorski 35A

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Motor starter/Motor starter combination
  • 1 KOM
  • SCHNEIDER

Technical specifications

With transformer

Number of indicator lights

0

Width

78mm

Suitable for emergency stop

Supporting protocol for TCP/IP

Number of command positions

1

Overload release current setting

3.7 .. 5.5A

Height

160mm

Number of auxiliary contacts as normally open contact

0

Supporting protocol for ASI

Rated operation power at AC-3, 400 V

2.2kW

Supporting protocol for LON

Rated operation current Ie

5.5A

Number of auxiliary contacts as normally closed contact

0

Depth

108mm

Supporting protocol for SUCONET

Supporting protocol for INTERBUS

Supporting protocol for CAN

Supporting protocol for Data-Highway

Supporting protocol for PROFIBUS

Supporting protocol for DeviceNet

Supporting protocol for Modbus

Rail mounting possible

Type of electrical connection for auxiliary- and control current circuit

Screw connection

With short-circuit release

Degree of protection (IP)

IP65

Supporting protocol for SERCOS

Rated control supply voltage Us at DC

- .. -V

External reset possible

Rated control supply voltage Us at AC 50HZ

380 .. 380V

Type of electrical connection of main circuit

Screw connection

Rated control supply voltage Us at AC 60HZ

380 .. 380V

Supporting protocol for INTERBUS-Safety

Release class

CLASS 10 A

With fuse

Supporting protocol for other bus systems

Supporting protocol for PROFINET IO

Supporting protocol for DeviceNet Safety

Voltage type for actuating

AC

Supporting protocol for PROFIsafe

Supporting protocol for EtherNet/IP

Rated operation power at AC-3, 230 V, 3-phase

1.1kW

Supporting protocol for Foundation Fieldbus

Supporting protocol for PROFINET CBA

Type of motor starter

Direct online starter (DOL)

Supporting protocol for SafetyBUS p

Supporting protocol for AS-Interface Safety at Work

Rated conditional short-circuit current, type 2, 230 V

-A

Temperature compensated overload protection

Rated conditional short-circuit current, type 1, 600 Y/347 V

-A

Rated conditional short-circuit current, type 2, 400 V

-A

Ambient temperature, upper operating limit

40°C

Rated power, 575 V, 60 Hz, 3-phase

3kW

Rated operation current at AC-3, 400 V

5.5A

Rated power, 460 V, 60 Hz, 3-phase

2.2kW

Rated conditional short-circuit current, type 1, 480 Y/277 V

-A

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.