Aleta.hr

Details

  • Low-voltage industrial components
  • Motor starter/Motor starter combination
  • 1 KOM
  • SCHNEIDER

Technical specifications

Width78mm
With transformerNo
Rated operation power at AC-3, 400 V4kW
Height160mm
Depth108mm
Suitable for emergency stopNo
Supporting protocol for ModbusNo
Number of command positions2
Supporting protocol for CANNo
Number of auxiliary contacts as normally open contact0
Rated control supply voltage Us at AC 60HZ380 - 400V
Supporting protocol for PROFIBUSNo
Supporting protocol for DeviceNetNo
Supporting protocol for ASINo
Rail mounting possibleNo
Supporting protocol for TCP/IPNo
Number of auxiliary contacts as normally closed contact0
Number of indicator lights1
Supporting protocol for SUCONETNo
Supporting protocol for SERCOSNo
Degree of protection (IP)IP65
Supporting protocol for INTERBUSNo
Supporting protocol for other bus systemsNo
Supporting protocol for Data-HighwayNo
Supporting protocol for LONNo
Rated control supply voltage Us at AC 50HZ380 - 400V
External reset possibleYes
Rated control supply voltage Us at DC- - -V
Rated operation current Ie11.5A
Overload release current setting8 - 11.5A
Supporting protocol for INTERBUS-SafetyNo
Supporting protocol for PROFIsafeNo
Supporting protocol for SafetyBUS pNo
With short-circuit releaseNo
Type of electrical connection of main circuitScrew connection
Voltage type for actuatingAC
Rated conditional short-circuit current, type 2, 400 V-A
Rated operation power at AC-3, 230 V, 3-phase2.2kW
Type of electrical connection for auxiliary- and control current circuitScrew connection
Rated conditional short-circuit current, type 1, 480 Y/277 V-A
With fuseNo
Rated conditional short-circuit current, type 2, 230 V-A
Supporting protocol for DeviceNet SafetyNo
Rated power, 460 V, 60 Hz, 3-phase5.5kW
Supporting protocol for AS-Interface Safety at WorkNo
Temperature compensated overload protectionYes
Supporting protocol for PROFINET IONo
Rated operation current at AC-3, 400 V11.5A
Supporting protocol for PROFINET CBANo
Type of motor starterDirect online starter (DOL)
Supporting protocol for EtherNet/IPNo
Release classCLASS 10 A
Ambient temperature, upper operating limit40°C
Supporting protocol for Foundation FieldbusNo
Rated power, 575 V, 60 Hz, 3-phase5.5kW
Rated conditional short-circuit current, type 1, 600 Y/347 V-A
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

LE1M35Q716 | Pokretac Motorski 35A

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Motor starter/Motor starter combination
  • 1 KOM
  • SCHNEIDER

Technical specifications

Width

78mm

With transformer

Rated operation power at AC-3, 400 V

4kW

Height

160mm

Depth

108mm

Suitable for emergency stop

Supporting protocol for Modbus

Number of command positions

2

Supporting protocol for CAN

Number of auxiliary contacts as normally open contact

0

Rated control supply voltage Us at AC 60HZ

380 .. 400V

Supporting protocol for PROFIBUS

Supporting protocol for DeviceNet

Supporting protocol for ASI

Rail mounting possible

Supporting protocol for TCP/IP

Number of auxiliary contacts as normally closed contact

0

Number of indicator lights

1

Supporting protocol for SUCONET

Supporting protocol for SERCOS

Degree of protection (IP)

IP65

Supporting protocol for INTERBUS

Supporting protocol for other bus systems

Supporting protocol for Data-Highway

Supporting protocol for LON

Rated control supply voltage Us at AC 50HZ

380 .. 400V

External reset possible

Rated control supply voltage Us at DC

- .. -V

Rated operation current Ie

11.5A

Overload release current setting

8 .. 11.5A

Supporting protocol for INTERBUS-Safety

Supporting protocol for PROFIsafe

Supporting protocol for SafetyBUS p

With short-circuit release

Type of electrical connection of main circuit

Screw connection

Voltage type for actuating

AC

Rated conditional short-circuit current, type 2, 400 V

-A

Rated operation power at AC-3, 230 V, 3-phase

2.2kW

Type of electrical connection for auxiliary- and control current circuit

Screw connection

Rated conditional short-circuit current, type 1, 480 Y/277 V

-A

With fuse

Rated conditional short-circuit current, type 2, 230 V

-A

Supporting protocol for DeviceNet Safety

Rated power, 460 V, 60 Hz, 3-phase

5.5kW

Supporting protocol for AS-Interface Safety at Work

Temperature compensated overload protection

Supporting protocol for PROFINET IO

Rated operation current at AC-3, 400 V

11.5A

Supporting protocol for PROFINET CBA

Type of motor starter

Direct online starter (DOL)

Supporting protocol for EtherNet/IP

Release class

CLASS 10 A

Ambient temperature, upper operating limit

40°C

Supporting protocol for Foundation Fieldbus

Rated power, 575 V, 60 Hz, 3-phase

5.5kW

Rated conditional short-circuit current, type 1, 600 Y/347 V

-A