Technical specifications
Width
78mm
With transformer
Rated operation power at AC-3, 400 V
4kW
Height
160mm
Depth
108mm
Suitable for emergency stop
Supporting protocol for Modbus
Number of command positions
2
Supporting protocol for CAN
Number of auxiliary contacts as normally open contact
0
Rated control supply voltage Us at AC 60HZ
380 .. 400V
Supporting protocol for PROFIBUS
Supporting protocol for DeviceNet
Supporting protocol for ASI
Rail mounting possible
Supporting protocol for TCP/IP
Number of auxiliary contacts as normally closed contact
0
Number of indicator lights
1
Supporting protocol for SUCONET
Supporting protocol for SERCOS
Degree of protection (IP)
IP65
Supporting protocol for INTERBUS
Supporting protocol for other bus systems
Supporting protocol for Data-Highway
Supporting protocol for LON
Rated control supply voltage Us at AC 50HZ
380 .. 400V
External reset possible
Rated control supply voltage Us at DC
- .. -V
Rated operation current Ie
11.5A
Overload release current setting
8 .. 11.5A
Supporting protocol for INTERBUS-Safety
Supporting protocol for PROFIsafe
Supporting protocol for SafetyBUS p
With short-circuit release
Type of electrical connection of main circuit
Screw connection
Voltage type for actuating
AC
Rated conditional short-circuit current, type 2, 400 V
-A
Rated operation power at AC-3, 230 V, 3-phase
2.2kW
Type of electrical connection for auxiliary- and control current circuit
Screw connection
Rated conditional short-circuit current, type 1, 480 Y/277 V
-A
With fuse
Rated conditional short-circuit current, type 2, 230 V
-A
Supporting protocol for DeviceNet Safety
Rated power, 460 V, 60 Hz, 3-phase
5.5kW
Supporting protocol for AS-Interface Safety at Work
Temperature compensated overload protection
Supporting protocol for PROFINET IO
Rated operation current at AC-3, 400 V
11.5A
Supporting protocol for PROFINET CBA
Type of motor starter
Direct online starter (DOL)
Supporting protocol for EtherNet/IP
Release class
CLASS 10 A
Ambient temperature, upper operating limit
40°C
Supporting protocol for Foundation Fieldbus
Rated power, 575 V, 60 Hz, 3-phase
5.5kW
Rated conditional short-circuit current, type 1, 600 Y/347 V
-A