Aleta.hr

Details

  • Low-voltage industrial components
  • Motor starter/Motor starter combination
  • 1 KOM
  • SCHNEIDER

Technical specifications

Number of auxiliary contacts as normally closed contact0
Suitable for emergency stopNo
Rated operation power at AC-3, 400 V5.5kW
Depth108mm
Rated operation current Ie14A
Overload release current setting10 - 14A
Height160mm
With transformerNo
Number of command positions1
Number of indicator lights0
Number of auxiliary contacts as normally open contact0
Width78mm
Supporting protocol for DeviceNetNo
Supporting protocol for ASINo
Supporting protocol for LONNo
Supporting protocol for other bus systemsNo
Supporting protocol for ModbusNo
Rated control supply voltage Us at AC 60HZ380 - 380V
Supporting protocol for TCP/IPNo
Supporting protocol for INTERBUSNo
External reset possibleNo
Supporting protocol for PROFIBUSNo
Supporting protocol for Data-HighwayNo
Rail mounting possibleNo
Rated control supply voltage Us at AC 50HZ380 - 380V
Degree of protection (IP)IP65
Supporting protocol for SUCONETNo
Supporting protocol for CANNo
Rated control supply voltage Us at DC- - -V
With short-circuit releaseNo
Supporting protocol for AS-Interface Safety at WorkNo
With fuseNo
Type of electrical connection of main circuitScrew connection
Supporting protocol for INTERBUS-SafetyNo
Type of electrical connection for auxiliary- and control current circuitScrew connection
Release classCLASS 10 A
Supporting protocol for SERCOSNo
Supporting protocol for SafetyBUS pNo
Supporting protocol for DeviceNet SafetyNo
Voltage type for actuatingAC
Temperature compensated overload protectionYes
Supporting protocol for PROFIsafeNo
Supporting protocol for PROFINET CBANo
Supporting protocol for EtherNet/IPNo
Rated operation power at AC-3, 230 V, 3-phase3kW
Rated power, 460 V, 60 Hz, 3-phase5.5kW
Ambient temperature, upper operating limit40°C
Type of motor starterDirect online starter (DOL)
Supporting protocol for PROFINET IONo
Rated operation current at AC-3, 400 V14A
Rated conditional short-circuit current, type 2, 400 V-A
Rated conditional short-circuit current, type 2, 230 V-A
Supporting protocol for Foundation FieldbusNo
Rated conditional short-circuit current, type 1, 480 Y/277 V-A
Rated power, 575 V, 60 Hz, 3-phase7.5kW
Rated conditional short-circuit current, type 1, 600 Y/347 V-A
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

LE1M35Q721 | Pokretac Motorski 35A

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Motor starter/Motor starter combination
  • 1 KOM
  • SCHNEIDER

Technical specifications

Number of auxiliary contacts as normally closed contact

0

Suitable for emergency stop

Rated operation power at AC-3, 400 V

5.5kW

Depth

108mm

Rated operation current Ie

14A

Overload release current setting

10 .. 14A

Height

160mm

With transformer

Number of command positions

1

Number of indicator lights

0

Number of auxiliary contacts as normally open contact

0

Width

78mm

Supporting protocol for DeviceNet

Supporting protocol for ASI

Supporting protocol for LON

Supporting protocol for other bus systems

Supporting protocol for Modbus

Rated control supply voltage Us at AC 60HZ

380 .. 380V

Supporting protocol for TCP/IP

Supporting protocol for INTERBUS

External reset possible

Supporting protocol for PROFIBUS

Supporting protocol for Data-Highway

Rail mounting possible

Rated control supply voltage Us at AC 50HZ

380 .. 380V

Degree of protection (IP)

IP65

Supporting protocol for SUCONET

Supporting protocol for CAN

Rated control supply voltage Us at DC

- .. -V

With short-circuit release

Supporting protocol for AS-Interface Safety at Work

With fuse

Type of electrical connection of main circuit

Screw connection

Supporting protocol for INTERBUS-Safety

Type of electrical connection for auxiliary- and control current circuit

Screw connection

Release class

CLASS 10 A

Supporting protocol for SERCOS

Supporting protocol for SafetyBUS p

Supporting protocol for DeviceNet Safety

Voltage type for actuating

AC

Temperature compensated overload protection

Supporting protocol for PROFIsafe

Supporting protocol for PROFINET CBA

Supporting protocol for EtherNet/IP

Rated operation power at AC-3, 230 V, 3-phase

3kW

Rated power, 460 V, 60 Hz, 3-phase

5.5kW

Ambient temperature, upper operating limit

40°C

Type of motor starter

Direct online starter (DOL)

Supporting protocol for PROFINET IO

Rated operation current at AC-3, 400 V

14A

Rated conditional short-circuit current, type 2, 400 V

-A

Rated conditional short-circuit current, type 2, 230 V

-A

Supporting protocol for Foundation Fieldbus

Rated conditional short-circuit current, type 1, 480 Y/277 V

-A

Rated power, 575 V, 60 Hz, 3-phase

7.5kW

Rated conditional short-circuit current, type 1, 600 Y/347 V

-A

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.