Technical specifications

Width78mm
Height160mm
With transformerNo
Rated operation power at AC-3, 400 V7.5kW
Number of auxiliary contacts as normally open contact0
Depth108mm
Number of command positions1
Rated operation current Ie16A
Number of indicator lights0
Suitable for emergency stopNo
Overload release current setting12 - 16A
Supporting protocol for LONNo
Supporting protocol for TCP/IPNo
Supporting protocol for ASINo
Number of auxiliary contacts as normally closed contact0
Supporting protocol for INTERBUSNo
Supporting protocol for Data-HighwayNo
Supporting protocol for PROFIBUSNo
Supporting protocol for ModbusNo
Supporting protocol for CANNo
Supporting protocol for DeviceNetNo
Supporting protocol for other bus systemsNo
Supporting protocol for SUCONETNo
Rail mounting possibleNo
Rated control supply voltage Us at DC- - -V
Supporting protocol for INTERBUS-SafetyNo
Degree of protection (IP)IP65
Supporting protocol for SERCOSNo
Rated control supply voltage Us at AC 50HZ380 - 380V
Rated control supply voltage Us at AC 60HZ380 - 380V
External reset possibleNo
Release classCLASS 10 A
With fuseNo
Supporting protocol for AS-Interface Safety at WorkNo
Supporting protocol for DeviceNet SafetyNo
Type of electrical connection for auxiliary- and control current circuitScrew connection
With short-circuit releaseNo
Type of electrical connection of main circuitScrew connection
Supporting protocol for EtherNet/IPNo
Supporting protocol for Foundation FieldbusNo
Supporting protocol for PROFINET CBANo
Supporting protocol for PROFIsafeNo
Voltage type for actuatingAC
Rated power, 460 V, 60 Hz, 3-phase7.5kW
Supporting protocol for SafetyBUS pNo
Supporting protocol for PROFINET IONo
Type of motor starterDirect online starter (DOL)
Rated operation power at AC-3, 230 V, 3-phase3.7kW
Rated power, 575 V, 60 Hz, 3-phase9kW
Rated conditional short-circuit current, type 1, 480 Y/277 V-A
Temperature compensated overload protectionYes
Rated conditional short-circuit current, type 2, 230 V-A
Rated conditional short-circuit current, type 2, 400 V-A
Ambient temperature, upper operating limit40°C
Rated conditional short-circuit current, type 1, 600 Y/347 V-A
Rated operation current at AC-3, 400 V16A
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

LE1M35Q722 | Pokretac Motorski 35A

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Motor starter/Motor starter combination
  • 1 KOM
  • SCHNEIDER

Technical specifications

Width

78mm

Height

160mm

With transformer

Rated operation power at AC-3, 400 V

7.5kW

Number of auxiliary contacts as normally open contact

0

Depth

108mm

Number of command positions

1

Rated operation current Ie

16A

Number of indicator lights

0

Suitable for emergency stop

Overload release current setting

12 .. 16A

Supporting protocol for LON

Supporting protocol for TCP/IP

Supporting protocol for ASI

Number of auxiliary contacts as normally closed contact

0

Supporting protocol for INTERBUS

Supporting protocol for Data-Highway

Supporting protocol for PROFIBUS

Supporting protocol for Modbus

Supporting protocol for CAN

Supporting protocol for DeviceNet

Supporting protocol for other bus systems

Supporting protocol for SUCONET

Rail mounting possible

Rated control supply voltage Us at DC

- .. -V

Supporting protocol for INTERBUS-Safety

Degree of protection (IP)

IP65

Supporting protocol for SERCOS

Rated control supply voltage Us at AC 50HZ

380 .. 380V

Rated control supply voltage Us at AC 60HZ

380 .. 380V

External reset possible

Release class

CLASS 10 A

With fuse

Supporting protocol for AS-Interface Safety at Work

Supporting protocol for DeviceNet Safety

Type of electrical connection for auxiliary- and control current circuit

Screw connection

With short-circuit release

Type of electrical connection of main circuit

Screw connection

Supporting protocol for EtherNet/IP

Supporting protocol for Foundation Fieldbus

Supporting protocol for PROFINET CBA

Supporting protocol for PROFIsafe

Voltage type for actuating

AC

Rated power, 460 V, 60 Hz, 3-phase

7.5kW

Supporting protocol for SafetyBUS p

Supporting protocol for PROFINET IO

Type of motor starter

Direct online starter (DOL)

Rated operation power at AC-3, 230 V, 3-phase

3.7kW

Rated power, 575 V, 60 Hz, 3-phase

9kW

Rated conditional short-circuit current, type 1, 480 Y/277 V

-A

Temperature compensated overload protection

Rated conditional short-circuit current, type 2, 230 V

-A

Rated conditional short-circuit current, type 2, 400 V

-A

Ambient temperature, upper operating limit

40°C

Rated conditional short-circuit current, type 1, 600 Y/347 V

-A

Rated operation current at AC-3, 400 V

16A

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.