Aleta.hr

Details

  • Low-voltage industrial components
  • Motor starter/Motor starter combination
  • 1 KOM
  • SCHNEIDER

Technical specifications

Overload release current setting- - -A
Temperature compensated overload protectionYes
Type of motor starterReversing starter
Rated control supply voltage Us at AC 50HZ110 - 240V
With short-circuit releaseYes
Rated control supply voltage Us at AC 60HZ110 - 240V
Rated control supply voltage Us at DC110 - 220V
Rated operation power at AC-3, 230 V, 3-phase3kW
Voltage type for actuatingAC/DC
Rated operation power at AC-3, 400 V5.5kW
Rated power, 460 V, 60 Hz, 3-phase5.5kW
Rated power, 575 V, 60 Hz, 3-phase5.5kW
Rated operation current Ie12A
Rated operation current at AC-3, 400 V12A
Supporting protocol for other bus systemsNo
Width45mm
Height224mm
Depth126mm
Rated conditional short-circuit current, type 2, 230 V50000A
Rated conditional short-circuit current, type 1, 600 Y/347 V4000A
Rated conditional short-circuit current, type 1, 480 Y/277 V10000A
Rated conditional short-circuit current, type 2, 400 V50000A
Number of auxiliary contacts as normally open contact1
Number of auxiliary contacts as normally closed contact1
Type of electrical connection of main circuitScrew connection
Rail mounting possibleYes
Ambient temperature, upper operating limit70°C
Type of electrical connection for auxiliary- and control current circuitScrew connection
Number of command positions3
With transformerNo
Suitable for emergency stopNo
Coordination class according to IEC 60947-4-3Class 2
Number of indicator lights0
External reset possibleNo
With fuseNo
Degree of protection (IP)IP20
Supporting protocol for TCP/IPNo
Supporting protocol for PROFIBUSNo
Supporting protocol for INTERBUSNo
Supporting protocol for CANNo
Supporting protocol for ASINo
Supporting protocol for ModbusNo
Supporting protocol for Data-HighwayNo
Supporting protocol for DeviceNetNo
Supporting protocol for PROFINET IONo
Supporting protocol for SUCONETNo
Supporting protocol for PROFINET CBANo
Supporting protocol for LONNo
Supporting protocol for SERCOSNo
Supporting protocol for Foundation FieldbusNo
Supporting protocol for EtherNet/IPNo
Supporting protocol for AS-Interface Safety at WorkNo
Supporting protocol for INTERBUS-SafetyNo
Supporting protocol for DeviceNet SafetyNo
Supporting protocol for PROFIsafeNo
Supporting protocol for SafetyBUS pNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

LU2B12FU

Main Product Image

Details

  • Low-voltage industrial components
  • Motor starter/Motor starter combination
  • 1 KOM
  • SCHNEIDER

Technical specifications

Overload release current setting

- .. -A

Temperature compensated overload protection

Type of motor starter

Reversing starter

Rated control supply voltage Us at AC 50HZ

110 .. 240V

With short-circuit release

Rated control supply voltage Us at AC 60HZ

110 .. 240V

Rated control supply voltage Us at DC

110 .. 220V

Rated operation power at AC-3, 230 V, 3-phase

3kW

Voltage type for actuating

AC/DC

Rated operation power at AC-3, 400 V

5.5kW

Rated power, 460 V, 60 Hz, 3-phase

5.5kW

Rated power, 575 V, 60 Hz, 3-phase

5.5kW

Rated operation current Ie

12A

Rated operation current at AC-3, 400 V

12A

Supporting protocol for other bus systems

Width

45mm

Height

224mm

Depth

126mm

Rated conditional short-circuit current, type 2, 230 V

50000A

Rated conditional short-circuit current, type 1, 600 Y/347 V

4000A

Rated conditional short-circuit current, type 1, 480 Y/277 V

10000A

Rated conditional short-circuit current, type 2, 400 V

50000A

Number of auxiliary contacts as normally open contact

1

Number of auxiliary contacts as normally closed contact

1

Type of electrical connection of main circuit

Screw connection

Rail mounting possible

Ambient temperature, upper operating limit

70°C

Type of electrical connection for auxiliary- and control current circuit

Screw connection

Number of command positions

3

With transformer

Suitable for emergency stop

Coordination class according to IEC 60947-4-3

Class 2

Number of indicator lights

0

External reset possible

With fuse

Degree of protection (IP)

IP20

Supporting protocol for TCP/IP

Supporting protocol for PROFIBUS

Supporting protocol for INTERBUS

Supporting protocol for CAN

Supporting protocol for ASI

Supporting protocol for Modbus

Supporting protocol for Data-Highway

Supporting protocol for DeviceNet

Supporting protocol for PROFINET IO

Supporting protocol for SUCONET

Supporting protocol for PROFINET CBA

Supporting protocol for LON

Supporting protocol for SERCOS

Supporting protocol for Foundation Fieldbus

Supporting protocol for EtherNet/IP

Supporting protocol for AS-Interface Safety at Work

Supporting protocol for INTERBUS-Safety

Supporting protocol for DeviceNet Safety

Supporting protocol for PROFIsafe

Supporting protocol for SafetyBUS p

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.