Details
- •Low-voltage industrial components
- •Motor starter/Motor starter combination
- •1 KOM
- •SCHNEIDER
Technical specifications
LU2B12FU | Baza 2 Smjera 12A 110-240V Ac/dc

Why Register?
- View wholesale prices with discounts
- Real-time stock availability
- Access invoices and dispatch notes
- Order history and frequently ordered items
- Exclusive B2B offers
and much more...
Details
- Low-voltage industrial components
- Motor starter/Motor starter combination
- 1 KOM
- SCHNEIDER
Technical specifications
With transformer
Height
224mm
Number of auxiliary contacts as normally open contact
1
Supporting protocol for LON
Depth
126mm
Suitable for emergency stop
Overload release current setting
- .. -A
Supporting protocol for PROFIBUS
Number of indicator lights
0
Number of command positions
3
Rated operation power at AC-3, 400 V
5.5kW
Supporting protocol for TCP/IP
Supporting protocol for CAN
Number of auxiliary contacts as normally closed contact
1
Supporting protocol for ASI
Rated operation current Ie
12A
Width
45mm
Supporting protocol for INTERBUS
Supporting protocol for SERCOS
Supporting protocol for AS-Interface Safety at Work
Rated control supply voltage Us at AC 50HZ
110 .. 240V
Rail mounting possible
With fuse
Type of electrical connection of main circuit
Screw connection
Degree of protection (IP)
IP20
Supporting protocol for PROFINET CBA
Supporting protocol for SUCONET
Rated control supply voltage Us at DC
110 .. 220V
With short-circuit release
Supporting protocol for DeviceNet
Rated control supply voltage Us at AC 60HZ
110 .. 240V
Supporting protocol for INTERBUS-Safety
Supporting protocol for EtherNet/IP
Supporting protocol for Modbus
Supporting protocol for PROFINET IO
Type of electrical connection for auxiliary- and control current circuit
Screw connection
Supporting protocol for other bus systems
External reset possible
Supporting protocol for Foundation Fieldbus
Supporting protocol for Data-Highway
Supporting protocol for DeviceNet Safety
Rated operation current at AC-3, 400 V
12A
Voltage type for actuating
AC/DC
Supporting protocol for SafetyBUS p
Temperature compensated overload protection
Rated conditional short-circuit current, type 1, 480 Y/277 V
10000A
Rated conditional short-circuit current, type 2, 400 V
50000A
Rated operation power at AC-3, 230 V, 3-phase
3kW
Rated conditional short-circuit current, type 2, 230 V
50000A
Rated power, 460 V, 60 Hz, 3-phase
5.5kW
Coordination class according to IEC 60947-4-3
Class 2
Ambient temperature, upper operating limit
70°C
Supporting protocol for PROFIsafe
Type of motor starter
Reversing starter
Rated power, 575 V, 60 Hz, 3-phase
5.5kW
Rated conditional short-circuit current, type 1, 600 Y/347 V
4000A