Details
- •Low-voltage industrial components
- •Motor starter/Motor starter combination
- •1 KOM
- •SCHNEIDER
Technical specifications
LU2B32FU | Baza 2 Smjera 32A 110-240V Ac/dc

Why Register?
- View wholesale prices with discounts
- Real-time stock availability
- Access invoices and dispatch notes
- Order history and frequently ordered items
- Exclusive B2B offers
and much more...
Details
- Low-voltage industrial components
- Motor starter/Motor starter combination
- 1 KOM
- SCHNEIDER
Technical specifications
Width
45mm
Number of auxiliary contacts as normally open contact
1
Supporting protocol for LON
Rated operation current Ie
32A
Supporting protocol for Modbus
Supporting protocol for ASI
Number of indicator lights
0
Number of command positions
3
Supporting protocol for TCP/IP
Supporting protocol for other bus systems
Supporting protocol for CAN
Supporting protocol for PROFIBUS
Rail mounting possible
Overload release current setting
- .. -A
Suitable for emergency stop
Depth
126mm
Number of auxiliary contacts as normally closed contact
1
Rated operation power at AC-3, 400 V
15kW
Supporting protocol for DeviceNet
Supporting protocol for SUCONET
Height
224mm
Rated control supply voltage Us at AC 50HZ
110 .. 240V
Supporting protocol for Data-Highway
Supporting protocol for INTERBUS
External reset possible
With transformer
Degree of protection (IP)
IP20
Rated control supply voltage Us at AC 60HZ
110 .. 240V
Rated operation current at AC-3, 400 V
32A
With short-circuit release
Supporting protocol for SafetyBUS p
Rated power, 575 V, 60 Hz, 3-phase
15kW
Voltage type for actuating
AC/DC
Ambient temperature, upper operating limit
70°C
Supporting protocol for SERCOS
Supporting protocol for DeviceNet Safety
Rated operation power at AC-3, 230 V, 3-phase
7.5kW
Supporting protocol for PROFIsafe
Supporting protocol for AS-Interface Safety at Work
Type of motor starter
Reversing starter
Supporting protocol for PROFINET CBA
Supporting protocol for EtherNet/IP
Supporting protocol for INTERBUS-Safety
Type of electrical connection for auxiliary- and control current circuit
Screw connection
Type of electrical connection of main circuit
Screw connection
Supporting protocol for PROFINET IO
Rated control supply voltage Us at DC
110 .. 220V
With fuse
Rated power, 460 V, 60 Hz, 3-phase
15kW
Supporting protocol for Foundation Fieldbus
Temperature compensated overload protection
Rated conditional short-circuit current, type 2, 230 V
50000A
Coordination class according to IEC 60947-4-3
Class 2
Rated conditional short-circuit current, type 1, 600 Y/347 V
4000A
Rated conditional short-circuit current, type 2, 400 V
50000A
Rated conditional short-circuit current, type 1, 480 Y/277 V
10000A