Details
- Low-voltage industrial components
- Motor starter/Motor starter combination
- 1 KOM
- SCHNEIDER
Technical specifications
Overload release current setting
- - -A
Temperature compensated overload protection
Yes
Type of motor starter
Direct online starter (DOL)
Rated control supply voltage Us at DC
24 - 220V
Rated control supply voltage Us at AC 60HZ
24 - 240V
Rated power, 575 V, 60 Hz, 3-phase
15kW
Voltage type for actuating
AC/DC
Rated operation power at AC-3, 400 V
15kW
Rated power, 460 V, 60 Hz, 3-phase
15kW
Rail mounting possible
Yes
Rated operation current at AC-3, 400 V
32A
Ambient temperature, upper operating limit
70°C
Rated control supply voltage Us at AC 50HZ
24 - 240V
Rated conditional short-circuit current, type 2, 400 V
50000A
Rated conditional short-circuit current, type 1, 480 Y/277 V
10000A
Number of command positions
3
Rated conditional short-circuit current, type 1, 600 Y/347 V
4000A
Supporting protocol for CAN
No
With short-circuit release
Yes
With transformer
No
Supporting protocol for SUCONET
No
Supporting protocol for ASI
No
Rated conditional short-circuit current, type 2, 230 V
50000A
Supporting protocol for Data-Highway
No
Rated operation current Ie
32A
Supporting protocol for TCP/IP
No
Supporting protocol for Modbus
No
Rated operation power at AC-3, 230 V, 3-phase
7.5kW
Supporting protocol for DeviceNet
No
Type of electrical connection for auxiliary- and control current circuit
Screw connection
Suitable for emergency stop
No
Coordination class according to IEC 60947-4-3
Class 2
Supporting protocol for PROFIBUS
No
Number of auxiliary contacts as normally open contact
1
With fuse
No
Type of electrical connection of main circuit
Screw connection
Number of indicator lights
0
Number of auxiliary contacts as normally closed contact
1
Degree of protection (IP)
IP20
Supporting protocol for INTERBUS
No
Supporting protocol for other bus systems
No
Width
45mm
External reset possible
No
Supporting protocol for PROFINET CBA
No
Height
154mm
Depth
126mm
Supporting protocol for PROFIsafe
No
Supporting protocol for SafetyBUS p
No
Supporting protocol for SERCOS
No
Supporting protocol for LON
No
Supporting protocol for PROFINET IO
No
Supporting protocol for DeviceNet Safety
No
Supporting protocol for EtherNet/IP
No
Supporting protocol for AS-Interface Safety at Work
No
Supporting protocol for Foundation Fieldbus
No
Supporting protocol for INTERBUS-Safety
No
From same serie
LUB320

Details
- Low-voltage industrial components
- Motor starter/Motor starter combination
- 1 KOM
- SCHNEIDER
Technical specifications
Overload release current setting
- .. -A
Temperature compensated overload protection
Type of motor starter
Direct online starter (DOL)
Rated control supply voltage Us at DC
24 .. 220V
Rated control supply voltage Us at AC 60HZ
24 .. 240V
Rated power, 575 V, 60 Hz, 3-phase
15kW
Voltage type for actuating
AC/DC
Rated operation power at AC-3, 400 V
15kW
Rated power, 460 V, 60 Hz, 3-phase
15kW
Rail mounting possible
Rated operation current at AC-3, 400 V
32A
Ambient temperature, upper operating limit
70°C
Rated control supply voltage Us at AC 50HZ
24 .. 240V
Rated conditional short-circuit current, type 2, 400 V
50000A
Rated conditional short-circuit current, type 1, 480 Y/277 V
10000A
Number of command positions
3
Rated conditional short-circuit current, type 1, 600 Y/347 V
4000A
Supporting protocol for CAN
With short-circuit release
With transformer
Supporting protocol for SUCONET
Supporting protocol for ASI
Rated conditional short-circuit current, type 2, 230 V
50000A
Supporting protocol for Data-Highway
Rated operation current Ie
32A
Supporting protocol for TCP/IP
Supporting protocol for Modbus
Rated operation power at AC-3, 230 V, 3-phase
7.5kW
Supporting protocol for DeviceNet
Type of electrical connection for auxiliary- and control current circuit
Screw connection
Suitable for emergency stop
Coordination class according to IEC 60947-4-3
Class 2
Supporting protocol for PROFIBUS
Number of auxiliary contacts as normally open contact
1
With fuse
Type of electrical connection of main circuit
Screw connection
Number of indicator lights
0
Number of auxiliary contacts as normally closed contact
1
Degree of protection (IP)
IP20
Supporting protocol for INTERBUS
Supporting protocol for other bus systems
Width
45mm
External reset possible
Supporting protocol for PROFINET CBA
Height
154mm
Depth
126mm
Supporting protocol for PROFIsafe
Supporting protocol for SafetyBUS p
Supporting protocol for SERCOS
Supporting protocol for LON
Supporting protocol for PROFINET IO
Supporting protocol for DeviceNet Safety
Supporting protocol for EtherNet/IP
Supporting protocol for AS-Interface Safety at Work
Supporting protocol for Foundation Fieldbus
Supporting protocol for INTERBUS-Safety
From same serie