Technical specifications
LUCAX6FU | Modul Stand. 0,15-0,6A110-240V

Why Register?
- View wholesale prices with discounts
- Real-time stock availability
- Access invoices and dispatch notes
- Order history and frequently ordered items
- Exclusive B2B offers
and much more...
Details
- Low-voltage industrial components
- Motor starter/Motor starter combination
- 1 KOM
- SCHNEIDER
Technical specifications
Depth
60mm
Width
45mm
Height
66mm
With transformer
Number of auxiliary contacts as normally closed contact
0
Suitable for emergency stop
Number of command positions
0
Number of auxiliary contacts as normally open contact
0
Supporting protocol for Data-Highway
Supporting protocol for other bus systems
Supporting protocol for DeviceNet
Rated control supply voltage Us at AC 60HZ
110 .. 240V
Supporting protocol for PROFIBUS
Supporting protocol for LON
Supporting protocol for INTERBUS-Safety
Supporting protocol for SERCOS
Rail mounting possible
Supporting protocol for SUCONET
Release class
CLASS 10
Rated control supply voltage Us at AC 50HZ
110 .. 240V
Supporting protocol for TCP/IP
Supporting protocol for CAN
With short-circuit release
Supporting protocol for Modbus
External reset possible
Supporting protocol for ASI
With fuse
Supporting protocol for INTERBUS
Number of indicator lights
0
Type of electrical connection of main circuit
Screw connection
Supporting protocol for DeviceNet Safety
Rated conditional short-circuit current, type 1, 600 Y/347 V
0.6A
Supporting protocol for PROFIsafe
Supporting protocol for AS-Interface Safety at Work
Ambient temperature, upper operating limit
70°C
Rated power, 575 V, 60 Hz, 3-phase
-kW
Rated conditional short-circuit current, type 1, 480 Y/277 V
0.15A
Supporting protocol for EtherNet/IP
Rated conditional short-circuit current, type 2, 400 V
0.6A
Supporting protocol for PROFINET IO
Rated power, 460 V, 60 Hz, 3-phase
-kW
Supporting protocol for PROFINET CBA
Rated operation power at AC-3, 230 V, 3-phase
-kW
Rated conditional short-circuit current, type 2, 230 V
0.15A
Type of electrical connection for auxiliary- and control current circuit
Screw connection
Supporting protocol for SafetyBUS p
Supporting protocol for Foundation Fieldbus
Voltage type for actuating
AC/DC
Coordination class according to IEC 60947-4-3
Class 2
Temperature compensated overload protection
Rated operation power at AC-3, 400 V
0.09kW
Rated operation current Ie
0.15A
Overload release current setting
0.15 .. 0.6A
Degree of protection (IP)
IP40
Rated control supply voltage Us at DC
110 .. 220V
Type of motor starter
Other
Rated operation current at AC-3, 400 V
0.6A