Details
- Low-voltage industrial components
- Trip block for power circuit-breaker
- 1 KOM
- SCHNEIDER
Technical specifications
Degree of protection (IP)
IP20
Number of auxiliary contacts as normally open contact
0
Number of auxiliary contacts as normally closed contact
0
Type of electrical connection of main circuit
Other
Rated control supply voltage Us at DC
24 - 24V
Rated control supply voltage Us at AC 50HZ
- - -V
Rated control supply voltage Us at AC 60HZ
- - -V
Voltage type for actuating
DC
Rated operation power at AC-3, 400 V
0.09kW
Supporting protocol for SERCOS
No
Supporting protocol for INTERBUS-Safety
No
Supporting protocol for AS-Interface Safety at Work
No
Supporting protocol for Foundation Fieldbus
No
Supporting protocol for Modbus
Yes
Supporting protocol for DeviceNet Safety
No
Supporting protocol for SUCONET
No
Supporting protocol for LON
No
Supporting protocol for DeviceNet
Yes
Supporting protocol for EtherNet/IP
No
Supporting protocol for PROFINET IO
No
Supporting protocol for PROFIsafe
No
Supporting protocol for SafetyBUS p
No
Supporting protocol for CAN
Yes
Supporting protocol for TCP/IP
No
Supporting protocol for PROFIBUS
Yes
Supporting protocol for Data-Highway
No
Supporting protocol for INTERBUS
No
Supporting protocol for PROFINET CBA
No
Supporting protocol for ASI
Yes
Supporting protocol for other bus systems
Yes
Rail mounting possible
No
End value adjustment range undelayed short-circuit release
8A
Initial value of the undelayed short-circuit release - setting range
8A
Release class
CLASS 20
Rated operation current Ie
0.6A
Rated power, 460 V, 60 Hz, 3-phase
-kW
With short-circuit release
Yes
Rated operation power at AC-3, 230 V, 3-phase
-kW
Rated operation current at AC-3, 400 V
0.6A
Rated power, 575 V, 60 Hz, 3-phase
-kW
Rated conditional short-circuit current, type 2, 400 V
-A
Ambient temperature, upper operating limit
70°C
Rated conditional short-circuit current, type 1, 480 Y/277 V
-A
Rated conditional short-circuit current, type 1, 600 Y/347 V
-A
Rated conditional short-circuit current, type 2, 230 V
-A
Temperature compensated overload protection
Yes
Type of motor starter
Other
Type of motor protection
Electronic release
Rated permanent current Iu
0.6A
With ground fault protection function
Yes
Number of poles
3
Overload release current setting
0.15 - 0.6A
Short-circuit release function
Undelayed
From same serie
LUCDX6BL

Details
- Low-voltage industrial components
- Trip block for power circuit-breaker
- 1 KOM
- SCHNEIDER
Technical specifications
Degree of protection (IP)
IP20
Number of auxiliary contacts as normally open contact
0
Number of auxiliary contacts as normally closed contact
0
Type of electrical connection of main circuit
Other
Rated control supply voltage Us at DC
24 .. 24V
Rated control supply voltage Us at AC 50HZ
- .. -V
Rated control supply voltage Us at AC 60HZ
- .. -V
Voltage type for actuating
DC
Rated operation power at AC-3, 400 V
0.09kW
Supporting protocol for SERCOS
Supporting protocol for INTERBUS-Safety
Supporting protocol for AS-Interface Safety at Work
Supporting protocol for Foundation Fieldbus
Supporting protocol for Modbus
Supporting protocol for DeviceNet Safety
Supporting protocol for SUCONET
Supporting protocol for LON
Supporting protocol for DeviceNet
Supporting protocol for EtherNet/IP
Supporting protocol for PROFINET IO
Supporting protocol for PROFIsafe
Supporting protocol for SafetyBUS p
Supporting protocol for CAN
Supporting protocol for TCP/IP
Supporting protocol for PROFIBUS
Supporting protocol for Data-Highway
Supporting protocol for INTERBUS
Supporting protocol for PROFINET CBA
Supporting protocol for ASI
Supporting protocol for other bus systems
Rail mounting possible
End value adjustment range undelayed short-circuit release
8A
Initial value of the undelayed short-circuit release - setting range
8A
Release class
CLASS 20
Rated operation current Ie
0.6A
Rated power, 460 V, 60 Hz, 3-phase
-kW
With short-circuit release
Rated operation power at AC-3, 230 V, 3-phase
-kW
Rated operation current at AC-3, 400 V
0.6A
Rated power, 575 V, 60 Hz, 3-phase
-kW
Rated conditional short-circuit current, type 2, 400 V
-A
Ambient temperature, upper operating limit
70°C
Rated conditional short-circuit current, type 1, 480 Y/277 V
-A
Rated conditional short-circuit current, type 1, 600 Y/347 V
-A
Rated conditional short-circuit current, type 2, 230 V
-A
Temperature compensated overload protection
Type of motor starter
Other
Type of motor protection
Electronic release
Rated permanent current Iu
0.6A
With ground fault protection function
Number of poles
3
Overload release current setting
0.15 .. 0.6A
Short-circuit release function
Undelayed
From same serie
We use cookies to enhance your experience.