Aleta.hr

Details

  • Low-voltage industrial components
  • Motor starter/motor starter combination
  • 1 KOM
  • SCHNEIDER

Technical specifications

Rated control supply voltage Us at AC 50HZ- - -V
Rated control supply voltage Us at AC 60HZ- - -V
Rated operation power at AC-3, 230 V, 3-phase-kW
With short-circuit releaseYes
Voltage type for actuatingDC
Rated power, 460 V, 60 Hz, 3-phase5.5kW
Type of motor starterOther
Rated power, 575 V, 60 Hz, 3-phase5.5kW
Rated operation current Ie3A
Rated conditional short-circuit current, type 1, 600 Y/347 V12A
Rated conditional short-circuit current, type 2, 230 V3A
Rated conditional short-circuit current, type 2, 400 V12A
Ambient temperature, upper operating limit70°C
Temperature compensated overload protectionYes
Rail mounting possibleYes
Number of auxiliary contacts as normally closed contact0
With fuseNo
Type of electrical connection of main circuitScrew connection
Rated control supply voltage Us at DC24 - 24V
With transformerNo
Number of indicator lights0
Suitable for emergency stopNo
Rated conditional short-circuit current, type 1, 480 Y/277 V3A
Coordination class according to IEC 60947-4-3Class 2
External reset possibleNo
Supporting protocol for CANNo
Number of auxiliary contacts as normally open contact0
Number of command positions0
Supporting protocol for INTERBUSNo
Rated operation current at AC-3, 400 V12A
Overload release current setting3 - 12A
Rated operation power at AC-3, 400 V5.5kW
Supporting protocol for TCP/IPNo
Type of electrical connection for auxiliary- and control current circuitScrew connection
Supporting protocol for PROFIBUSNo
Degree of protection (IP)IP40
Release classCLASS 10
Supporting protocol for ASINo
Supporting protocol for ModbusNo
Supporting protocol for SUCONETNo
Supporting protocol for LONNo
Supporting protocol for SERCOSNo
Supporting protocol for Foundation FieldbusNo
Supporting protocol for PROFINET IONo
Supporting protocol for PROFINET CBANo
Supporting protocol for Data-HighwayNo
Supporting protocol for DeviceNet SafetyNo
Supporting protocol for PROFIsafeNo
Supporting protocol for AS-Interface Safety at WorkNo
Width45mm
Supporting protocol for SafetyBUS pNo
Supporting protocol for EtherNet/IPNo
Depth60mm
Height66mm
Supporting protocol for INTERBUS-SafetyNo
Supporting protocol for other bus systemsNo
Supporting protocol for DeviceNetNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

LUCM12BL

Main Product Image

Details

  • Low-voltage industrial components
  • Motor starter/motor starter combination
  • 1 KOM
  • SCHNEIDER

Technical specifications

Rated control supply voltage Us at AC 50HZ

- .. -V

Rated control supply voltage Us at AC 60HZ

- .. -V

Rated operation power at AC-3, 230 V, 3-phase

-kW

With short-circuit release

Voltage type for actuating

DC

Rated power, 460 V, 60 Hz, 3-phase

5.5kW

Type of motor starter

Other

Rated power, 575 V, 60 Hz, 3-phase

5.5kW

Rated operation current Ie

3A

Rated conditional short-circuit current, type 1, 600 Y/347 V

12A

Rated conditional short-circuit current, type 2, 230 V

3A

Rated conditional short-circuit current, type 2, 400 V

12A

Ambient temperature, upper operating limit

70°C

Temperature compensated overload protection

Rail mounting possible

Number of auxiliary contacts as normally closed contact

0

With fuse

Type of electrical connection of main circuit

Screw connection

Rated control supply voltage Us at DC

24 .. 24V

With transformer

Number of indicator lights

0

Suitable for emergency stop

Rated conditional short-circuit current, type 1, 480 Y/277 V

3A

Coordination class according to IEC 60947-4-3

Class 2

External reset possible

Supporting protocol for CAN

Number of auxiliary contacts as normally open contact

0

Number of command positions

0

Supporting protocol for INTERBUS

Rated operation current at AC-3, 400 V

12A

Overload release current setting

3 .. 12A

Rated operation power at AC-3, 400 V

5.5kW

Supporting protocol for TCP/IP

Type of electrical connection for auxiliary- and control current circuit

Screw connection

Supporting protocol for PROFIBUS

Degree of protection (IP)

IP40

Release class

CLASS 10

Supporting protocol for ASI

Supporting protocol for Modbus

Supporting protocol for SUCONET

Supporting protocol for LON

Supporting protocol for SERCOS

Supporting protocol for Foundation Fieldbus

Supporting protocol for PROFINET IO

Supporting protocol for PROFINET CBA

Supporting protocol for Data-Highway

Supporting protocol for DeviceNet Safety

Supporting protocol for PROFIsafe

Supporting protocol for AS-Interface Safety at Work

Width

45mm

Supporting protocol for SafetyBUS p

Supporting protocol for EtherNet/IP

Depth

60mm

Height

66mm

Supporting protocol for INTERBUS-Safety

Supporting protocol for other bus systems

Supporting protocol for DeviceNet