  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation prot.
  • 1 KOM
  • SCHNEIDER

Technical specifications

Number of auxiliary contacts as normally open contact0
Number of auxiliary contacts as normally closed contact0
Degree of protection (IP)IP30
Number of poles4
Overload release current setting70 - 100A
Number of auxiliary contacts as change-over contact0
Rated voltage690 - 690V
Rated permanent current Iu32A
Motor drive integratedNo
Position of connection for main current circuitFront side
Type of electrical connection of main circuitScrew connection
Adjustment range short-term delayed short-circuit release0 - 0A
With switched-off indicatorNo
Adjustment range undelayed short-circuit release400 - 400A
Integrated earth fault protectionNo
Suitable for DIN rail (top hat rail) mountingNo
Type of control elementRocker lever
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz36kA
Device constructionBuilt-in device fixed built-in technique
Complete device with protection unitYes
Motor drive optionalYes
With under voltage releaseNo
DIN rail (top hat rail) mounting optionalNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

Item is no longer available for sale!

LV429655

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation prot.
  • 1 KOM
  • SCHNEIDER

Technical specifications

Number of auxiliary contacts as normally open contact

0

Number of auxiliary contacts as normally closed contact

0

Degree of protection (IP)

IP30

Number of poles

4

Overload release current setting

70 .. 100A

Number of auxiliary contacts as change-over contact

0

Rated voltage

690 .. 690V

Rated permanent current Iu

32A

Motor drive integrated

Position of connection for main current circuit

Front side

Type of electrical connection of main circuit

Screw connection

Adjustment range short-term delayed short-circuit release

0 .. 0A

With switched-off indicator

Adjustment range undelayed short-circuit release

400 .. 400A

Integrated earth fault protection

Suitable for DIN rail (top hat rail) mounting

Type of control element

Rocker lever

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

36kA

Device construction

Built-in device fixed built-in technique

Complete device with protection unit

Motor drive optional

With under voltage release

DIN rail (top hat rail) mounting optional