Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation prot.
  • 1 KOM
  • SCHNEIDER

Technical specifications

Number of auxiliary contacts as normally open contact0
Overload release current setting70 - 100A
Degree of protection (IP)IP30
Suitable for DIN rail (top hat rail) mountingNo
Number of auxiliary contacts as change-over contact0
Type of control elementRocker lever
Number of auxiliary contacts as normally closed contact0
Type of electrical connection of main circuitScrew connection
Adjustment range short-term delayed short-circuit release0 - 0A
With switched-off indicatorNo
Adjustment range undelayed short-circuit release800 - 800A
Motor drive integratedNo
Position of connection for main current circuitFront side
Complete device with protection unitYes
Motor drive optionalYes
Device constructionBuilt-in device fixed built-in technique
DIN rail (top hat rail) mounting optionalNo
With under voltage releaseNo
Integrated earth fault protectionNo
Rated permanent current Iu100A
Number of poles4
Rated voltage690 - 690V
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz70kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

Item is no longer available for sale!

LV429690

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation prot.
  • 1 KOM
  • SCHNEIDER

Technical specifications

Number of auxiliary contacts as normally open contact

0

Overload release current setting

70 .. 100A

Degree of protection (IP)

IP30

Suitable for DIN rail (top hat rail) mounting

Number of auxiliary contacts as change-over contact

0

Type of control element

Rocker lever

Number of auxiliary contacts as normally closed contact

0

Type of electrical connection of main circuit

Screw connection

Adjustment range short-term delayed short-circuit release

0 .. 0A

With switched-off indicator

Adjustment range undelayed short-circuit release

800 .. 800A

Motor drive integrated

Position of connection for main current circuit

Front side

Complete device with protection unit

Motor drive optional

Device construction

Built-in device fixed built-in technique

DIN rail (top hat rail) mounting optional

With under voltage release

Integrated earth fault protection

Rated permanent current Iu

100A

Number of poles

4

Rated voltage

690 .. 690V

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

70kA

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.