Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation prot.
  • 1 KOM
  • SCHNEIDER

Technical specifications

Degree of protection (IP)IP30
Number of poles3
Type of control elementRocker lever
Rated permanent current Iu100A
Number of auxiliary contacts as normally open contact0
Number of auxiliary contacts as normally closed contact0
Overload release current setting40 - 100A
Device constructionBuilt-in device fixed built-in technique
Type of electrical connection of main circuitScrew connection
Rated voltage690 - 690V
Motor drive optionalYes
Motor drive integratedNo
Number of auxiliary contacts as change-over contact0
Suitable for DIN rail (top hat rail) mountingNo
Adjustment range undelayed short-circuit release150 - 1500A
With switched-off indicatorNo
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz36kA
Adjustment range short-term delayed short-circuit release54 - 1000A
Position of connection for main current circuitFront side
DIN rail (top hat rail) mounting optionalNo
Complete device with protection unitYes
With under voltage releaseNo
Integrated earth fault protectionNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

LV429880

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation prot.
  • 1 KOM
  • SCHNEIDER

Technical specifications

Degree of protection (IP)

IP30

Number of poles

3

Type of control element

Rocker lever

Rated permanent current Iu

100A

Number of auxiliary contacts as normally open contact

0

Number of auxiliary contacts as normally closed contact

0

Overload release current setting

40 .. 100A

Device construction

Built-in device fixed built-in technique

Type of electrical connection of main circuit

Screw connection

Rated voltage

690 .. 690V

Motor drive optional

Motor drive integrated

Number of auxiliary contacts as change-over contact

0

Suitable for DIN rail (top hat rail) mounting

Adjustment range undelayed short-circuit release

150 .. 1500A

With switched-off indicator

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

36kA

Adjustment range short-term delayed short-circuit release

54 .. 1000A

Position of connection for main current circuit

Front side

DIN rail (top hat rail) mounting optional

Complete device with protection unit

With under voltage release

Integrated earth fault protection

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.