Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation prot.
  • 1 KOM
  • SCHNEIDER

Technical specifications

Number of auxiliary contacts as normally open contact0
Rated permanent current Iu125A
Type of electrical connection of main circuitScrew connection
Motor drive integratedNo
Rated voltage690 - 690V
Number of auxiliary contacts as change-over contact0
Number of poles3
Degree of protection (IP)IP30
Overload release current setting88 - 125A
Type of control elementRocker lever
Number of auxiliary contacts as normally closed contact0
Position of connection for main current circuitFront connection
With under voltage releaseNo
DIN rail (top hat rail) mounting optionalNo
Adjustment range undelayed short-circuit release1250 - 1250A
With switched-off indicatorNo
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz25kA
Motor drive optionalYes
Suitable for DIN rail (top hat rail) mountingNo
Complete device with protection unitYes
Adjustment range short-term delayed short-circuit release1250 - 1250A
Integrated earth fault protectionNo
Device constructionBuilt-in device fixed built-in technique
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

LV430311

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation prot.
  • 1 KOM
  • SCHNEIDER

Technical specifications

Number of auxiliary contacts as normally open contact

0

Rated permanent current Iu

125A

Type of electrical connection of main circuit

Screw connection

Motor drive integrated

Rated voltage

690 .. 690V

Number of auxiliary contacts as change-over contact

0

Number of poles

3

Degree of protection (IP)

IP30

Overload release current setting

88 .. 125A

Type of control element

Rocker lever

Number of auxiliary contacts as normally closed contact

0

Position of connection for main current circuit

Front connection

With under voltage release

DIN rail (top hat rail) mounting optional

Adjustment range undelayed short-circuit release

1250 .. 1250A

With switched-off indicator

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

25kA

Motor drive optional

Suitable for DIN rail (top hat rail) mounting

Complete device with protection unit

Adjustment range short-term delayed short-circuit release

1250 .. 1250A

Integrated earth fault protection

Device construction

Built-in device fixed built-in technique

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.