Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation prot.
  • 1 KOM
  • SCHNEIDER

Technical specifications

Number of auxiliary contacts as normally open contact0
Degree of protection (IP)IP30
Position of connection for main current circuitFront side
Type of electrical connection of main circuitScrew connection
Overload release current setting56 - 80A
Motor drive integratedNo
With switched-off indicatorNo
Number of auxiliary contacts as change-over contact0
Type of control elementRocker lever
Adjustment range undelayed short-circuit release630 - 630A
Adjustment range short-term delayed short-circuit release0 - 0A
Number of auxiliary contacts as normally closed contact0
Rated voltage690 - 690V
Number of poles4
Rated permanent current Iu80A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz70kA
DIN rail (top hat rail) mounting optionalNo
With under voltage releaseNo
Complete device with protection unitYes
Suitable for DIN rail (top hat rail) mountingNo
Integrated earth fault protectionNo
Device constructionBuilt-in device fixed built-in technique
Motor drive optionalYes
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

Item is no longer available for sale!

LV430693

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation prot.
  • 1 KOM
  • SCHNEIDER

Technical specifications

Number of auxiliary contacts as normally open contact

0

Degree of protection (IP)

IP30

Position of connection for main current circuit

Front side

Type of electrical connection of main circuit

Screw connection

Overload release current setting

56 .. 80A

Motor drive integrated

With switched-off indicator

Number of auxiliary contacts as change-over contact

0

Type of control element

Rocker lever

Adjustment range undelayed short-circuit release

630 .. 630A

Adjustment range short-term delayed short-circuit release

0 .. 0A

Number of auxiliary contacts as normally closed contact

0

Rated voltage

690 .. 690V

Number of poles

4

Rated permanent current Iu

80A

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

70kA

DIN rail (top hat rail) mounting optional

With under voltage release

Complete device with protection unit

Suitable for DIN rail (top hat rail) mounting

Integrated earth fault protection

Device construction

Built-in device fixed built-in technique

Motor drive optional

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.