Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation prot.
  • 1 KOM
  • SCHNEIDER

Technical specifications

Overload release current setting175 - 250A
Number of auxiliary contacts as normally closed contact0
Rated permanent current Iu125A
Number of auxiliary contacts as change-over contact0
Number of auxiliary contacts as normally open contact0
Number of poles3
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz25kA
Type of electrical connection of main circuitScrew connection
Integrated earth fault protectionNo
Suitable for DIN rail (top hat rail) mountingNo
Type of control elementRocker lever
Degree of protection (IP)IP30
Motor drive optionalYes
Adjustment range undelayed short-circuit release1250 - 1250A
Adjustment range short-term delayed short-circuit release1250 - 1250A
With switched-off indicatorNo
Rated voltage690 - 690V
Position of connection for main current circuitFront connection
With under voltage releaseNo
Motor drive integratedNo
Complete device with protection unitYes
DIN rail (top hat rail) mounting optionalNo
Device constructionBuilt-in device fixed built-in technique
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

LV431113

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation prot.
  • 1 KOM
  • SCHNEIDER

Technical specifications

Overload release current setting

175 .. 250A

Number of auxiliary contacts as normally closed contact

0

Rated permanent current Iu

125A

Number of auxiliary contacts as change-over contact

0

Number of auxiliary contacts as normally open contact

0

Number of poles

3

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

25kA

Type of electrical connection of main circuit

Screw connection

Integrated earth fault protection

Suitable for DIN rail (top hat rail) mounting

Type of control element

Rocker lever

Degree of protection (IP)

IP30

Motor drive optional

Adjustment range undelayed short-circuit release

1250 .. 1250A

Adjustment range short-term delayed short-circuit release

1250 .. 1250A

With switched-off indicator

Rated voltage

690 .. 690V

Position of connection for main current circuit

Front connection

With under voltage release

Motor drive integrated

Complete device with protection unit

DIN rail (top hat rail) mounting optional

Device construction

Built-in device fixed built-in technique

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.