Technical specifications

Degree of protection (IP)IP30
Number of auxiliary contacts as normally open contact0
Rated permanent current Iu250A
Number of auxiliary contacts as change-over contact0
Number of poles4
Motor drive integratedNo
Number of auxiliary contacts as normally closed contact0
Rated voltage690 - 690V
Overload release current setting225 - 250A
Position of connection for main current circuitFront connection
Integrated earth fault protectionNo
Type of electrical connection of main circuitScrew connection
Suitable for DIN rail (top hat rail) mountingNo
Device constructionBuilt-in device fixed built-in technique
Adjustment range short-term delayed short-circuit release135 - 2500A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz25kA
Motor drive optionalYes
DIN rail (top hat rail) mounting optionalNo
With switched-off indicatorNo
Type of control elementRocker lever
With under voltage releaseNo
Complete device with protection unitYes
Adjustment range undelayed short-circuit release3000 - 3000A
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

Item is no longer available for sale!

LV431150

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation prot.
  • 1 KOM
  • SCHNEIDER

Technical specifications

Degree of protection (IP)

IP30

Number of auxiliary contacts as normally open contact

0

Rated permanent current Iu

250A

Number of auxiliary contacts as change-over contact

0

Number of poles

4

Motor drive integrated

Number of auxiliary contacts as normally closed contact

0

Rated voltage

690 .. 690V

Overload release current setting

225 .. 250A

Position of connection for main current circuit

Front connection

Integrated earth fault protection

Type of electrical connection of main circuit

Screw connection

Suitable for DIN rail (top hat rail) mounting

Device construction

Built-in device fixed built-in technique

Adjustment range short-term delayed short-circuit release

135 .. 2500A

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

25kA

Motor drive optional

DIN rail (top hat rail) mounting optional

With switched-off indicator

Type of control element

Rocker lever

With under voltage release

Complete device with protection unit

Adjustment range undelayed short-circuit release

3000 .. 3000A

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.