Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • SCHNEIDER

Technical specifications

Degree of protection (IP)IP40
Type of control elementToggle
Number of poles4
Number of auxiliary contacts as normally closed contact0
Number of auxiliary contacts as normally open contact0
Rated permanent current Iu250A
Overload release current setting- - -A
Motor drive integratedNo
Type of electrical connection of main circuitScrew connection
Number of auxiliary contacts as change-over contact0
Motor drive optionalYes
Rated voltage690 - 690V
Device constructionBuilt-in device fixed built-in technique
Adjustment range undelayed short-circuit release- - -A
Suitable for DIN rail (top hat rail) mountingNo
Integrated earth fault protectionNo
With under voltage releaseNo
With switched-off indicatorYes
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz25kA
Adjustment range short-term delayed short-circuit release- - -A
Position of connection for main current circuitFront side
Complete device with protection unitNo
DIN rail (top hat rail) mounting optionalYes
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

LV431395

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • SCHNEIDER

Technical specifications

Degree of protection (IP)

IP40

Type of control element

Toggle

Number of poles

4

Number of auxiliary contacts as normally closed contact

0

Number of auxiliary contacts as normally open contact

0

Rated permanent current Iu

250A

Overload release current setting

- .. -A

Motor drive integrated

Type of electrical connection of main circuit

Screw connection

Number of auxiliary contacts as change-over contact

0

Motor drive optional

Rated voltage

690 .. 690V

Device construction

Built-in device fixed built-in technique

Adjustment range undelayed short-circuit release

- .. -A

Suitable for DIN rail (top hat rail) mounting

Integrated earth fault protection

With under voltage release

With switched-off indicator

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

25kA

Adjustment range short-term delayed short-circuit release

- .. -A

Position of connection for main current circuit

Front side

Complete device with protection unit

DIN rail (top hat rail) mounting optional

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.