Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation prot.
  • 1 KOM
  • SCHNEIDER

Technical specifications

Degree of protection (IP)IP30
Type of control elementRocker lever
Number of poles3
Rated permanent current Iu125A
Number of auxiliary contacts as normally closed contact0
Number of auxiliary contacts as normally open contact0
Overload release current setting88 - 125A
Motor drive integratedNo
Type of electrical connection of main circuitScrew connection
Device constructionBuilt-in device fixed built-in technique
Number of auxiliary contacts as change-over contact0
Motor drive optionalYes
Rated voltage690 - 690V
Adjustment range undelayed short-circuit release1250 - 1250A
Suitable for DIN rail (top hat rail) mountingNo
Integrated earth fault protectionNo
With under voltage releaseNo
With switched-off indicatorNo
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz36kA
Adjustment range short-term delayed short-circuit release0 - 0A
Position of connection for main current circuitFront side
Complete device with protection unitYes
DIN rail (top hat rail) mounting optionalNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

LV431633

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation prot.
  • 1 KOM
  • SCHNEIDER

Technical specifications

Degree of protection (IP)

IP30

Type of control element

Rocker lever

Number of poles

3

Rated permanent current Iu

125A

Number of auxiliary contacts as normally closed contact

0

Number of auxiliary contacts as normally open contact

0

Overload release current setting

88 .. 125A

Motor drive integrated

Type of electrical connection of main circuit

Screw connection

Device construction

Built-in device fixed built-in technique

Number of auxiliary contacts as change-over contact

0

Motor drive optional

Rated voltage

690 .. 690V

Adjustment range undelayed short-circuit release

1250 .. 1250A

Suitable for DIN rail (top hat rail) mounting

Integrated earth fault protection

With under voltage release

With switched-off indicator

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

36kA

Adjustment range short-term delayed short-circuit release

0 .. 0A

Position of connection for main current circuit

Front side

Complete device with protection unit

DIN rail (top hat rail) mounting optional

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.