Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation prot.
  • 1 KOM
  • SCHNEIDER

Technical specifications

Number of auxiliary contacts as normally closed contact0
Number of auxiliary contacts as normally open contact0
Rated permanent current Iu160A
Number of auxiliary contacts as change-over contact0
Motor drive integratedNo
Number of poles4
Motor drive optionalYes
Rated voltage690 - 690V
Degree of protection (IP)IP30
Device constructionBuilt-in device fixed built-in technique
Type of electrical connection of main circuitScrew connection
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz36kA
Adjustment range undelayed short-circuit release240 - 2400A
Overload release current setting63 - 160A
With under voltage releaseNo
Type of control elementRocker lever
Suitable for DIN rail (top hat rail) mountingNo
Adjustment range short-term delayed short-circuit release86 - 1600A
Position of connection for main current circuitFront side
With switched-off indicatorNo
Integrated earth fault protectionNo
Complete device with protection unitYes
DIN rail (top hat rail) mounting optionalNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

Item is no longer available for sale!

LV431866

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation prot.
  • 1 KOM
  • SCHNEIDER

Technical specifications

Number of auxiliary contacts as normally closed contact

0

Number of auxiliary contacts as normally open contact

0

Rated permanent current Iu

160A

Number of auxiliary contacts as change-over contact

0

Motor drive integrated

Number of poles

4

Motor drive optional

Rated voltage

690 .. 690V

Degree of protection (IP)

IP30

Device construction

Built-in device fixed built-in technique

Type of electrical connection of main circuit

Screw connection

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

36kA

Adjustment range undelayed short-circuit release

240 .. 2400A

Overload release current setting

63 .. 160A

With under voltage release

Type of control element

Rocker lever

Suitable for DIN rail (top hat rail) mounting

Adjustment range short-term delayed short-circuit release

86 .. 1600A

Position of connection for main current circuit

Front side

With switched-off indicator

Integrated earth fault protection

Complete device with protection unit

DIN rail (top hat rail) mounting optional

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.