Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • SCHNEIDER

Technical specifications

Degree of protection (IP)IP40
Number of poles3
Type of control elementToggle
Number of auxiliary contacts as normally closed contact0
Number of auxiliary contacts as normally open contact0
Rated permanent current Iu400A
Overload release current setting160 - 400A
Motor drive integratedNo
Rated voltage690 - 690V
Type of electrical connection of main circuitScrew connection
Motor drive optionalYes
Device constructionBuilt-in device fixed built-in technique
Number of auxiliary contacts as change-over contact0
Adjustment range undelayed short-circuit release4800 - 4800A
Suitable for DIN rail (top hat rail) mountingNo
With switched-off indicatorYes
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz75kA
Adjustment range short-term delayed short-circuit release240 - 4000A
Position of connection for main current circuitFront side
DIN rail (top hat rail) mounting optionalNo
Complete device with protection unitYes
Integrated earth fault protectionNo
With under voltage releaseNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

LV433622

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • SCHNEIDER

Technical specifications

Degree of protection (IP)

IP40

Number of poles

3

Type of control element

Toggle

Number of auxiliary contacts as normally closed contact

0

Number of auxiliary contacts as normally open contact

0

Rated permanent current Iu

400A

Overload release current setting

160 .. 400A

Motor drive integrated

Rated voltage

690 .. 690V

Type of electrical connection of main circuit

Screw connection

Motor drive optional

Device construction

Built-in device fixed built-in technique

Number of auxiliary contacts as change-over contact

0

Adjustment range undelayed short-circuit release

4800 .. 4800A

Suitable for DIN rail (top hat rail) mounting

With switched-off indicator

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

75kA

Adjustment range short-term delayed short-circuit release

240 .. 4000A

Position of connection for main current circuit

Front side

DIN rail (top hat rail) mounting optional

Complete device with protection unit

Integrated earth fault protection

With under voltage release

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.