Details

  • Programmable logic controllers PLC
  • Fieldbus, decentr. periphery - analogue/digital I/O module
  • 1 KOM
  • SCHNEIDER

Technical specifications

Width71.7mm
Suitable for safety functionsNo
Number of HW-interfaces industrial Ethernet0
Number of HW-interfaces RS-4220
Height116mm
Number of HW-interfaces parallel0
Depth70.6mm
Time delay at signal exchange0 - 20ms
Number of HW-interfaces serial TTY0
Number of HW-interfaces RS-4850
Input current at signal 16.1mA
Supporting protocol for LONNo
Number of HW-interfaces RS-2320
Number of HW-interfaces USB0
Number of HW-interfaces other2
With optical interfaceNo
Type of voltage (input voltage)DC
Voltage type of supply voltageDC
Supporting protocol for PROFIBUSNo
Supporting protocol for ASINo
Supporting protocol for Data-HighwayNo
Supporting protocol for ModbusNo
Supporting protocol for INTERBUSNo
Analogue input, resistor temperatureYes
Supporting protocol for KNXNo
Analogue input, voltageNo
Analogue input, currentNo
Supporting protocol for other bus systemsNo
Analogue input signal configurableYes
Output current at digital output5A
Supporting protocol for TCP/IPNo
Supporting protocol for CANNo
Analogue output, voltageNo
Supporting protocol for DeviceNetNo
Supporting protocol for SUCONETNo
Output voltage at digital output250 - 250V
Analogue input, thermocoupleYes
Analogue output, currentNo
Analogue input, resistorNo
Short-circuit protection, digital outputs availableYes
Resolution of the analogue inputs-Bit
Analogue output signal configurableNo
Resolution of the analogue outputs-Bit
Type of electric connectionScrew connection
Type of digital outputOther
Fieldbus connection over separate bus coupler possibleNo
Rack-assembly possibleNo
Rail mounting possibleYes
IO link masterYes
Appendant operation agent (Ex ib)No
Supporting protocol for SERCOSNo
Number of interfaces PROFINET0
Wall mounting/direct mountingNo
Appendant operation agent (Ex ia)No
Supporting protocol for INTERBUS-SafetyNo
Number of HW-interfaces Wireless0
Supporting protocol for AS-Interface Safety at WorkNo
System accessoryNo
Front built-in possibleNo
Supporting protocol for EtherNet/IPYes
Supporting protocol for Foundation FieldbusNo
Supporting protocol for DeviceNet SafetyNo
Radio standard BluetoothNo
Radio standard Wi-Fi 802.11No
Supporting protocol for SafetyBUS pNo
Supply voltage AC 50 Hz- - -V
Supporting protocol for PROFIsafeNo
Supply voltage AC 60 Hz- - -V
Supporting protocol for PROFINET CBANo
Supporting protocol for PROFINET IONo
SIL according to IEC 61508None
Supply voltage DC19.2 - 26.4V
Permitted voltage at input19.8 - 25.2V
Radio standard GSMNo
Radio standard UMTSNo
Analogue outputs configurableNo
Type of output voltageAC
Analogue inputs configurableYes
Digital outputs configurableYes
Radio standard GPRSNo
Digital inputs configurableYes
Number of digital inputs6
Number of digital outputs3
Number of analogue inputs1
Number of analogue outputs0
Degree of protection (IP)IP2X