Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • SCHNEIDER

Technical specifications

Degree of protection (IP)IP30
Number of poles3
Type of control elementToggle
Number of auxiliary contacts as normally closed contact0
Number of auxiliary contacts as normally open contact0
Rated permanent current Iu160A
Motor drive integratedNo
Overload release current setting- - -A
Rated voltage750 - 750V
Type of electrical connection of main circuitScrew connection
Motor drive optionalYes
Device constructionBuilt-in device fixed built-in technique
Number of auxiliary contacts as change-over contact0
Adjustment range undelayed short-circuit release- - -A
Suitable for DIN rail (top hat rail) mountingNo
With switched-off indicatorYes
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz36kA
Adjustment range short-term delayed short-circuit release- - -A
Position of connection for main current circuitFront side
DIN rail (top hat rail) mounting optionalYes
Complete device with protection unitNo
Integrated earth fault protectionNo
With under voltage releaseNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

LV438103

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • SCHNEIDER

Technical specifications

Degree of protection (IP)

IP30

Number of poles

3

Type of control element

Toggle

Number of auxiliary contacts as normally closed contact

0

Number of auxiliary contacts as normally open contact

0

Rated permanent current Iu

160A

Motor drive integrated

Overload release current setting

- .. -A

Rated voltage

750 .. 750V

Type of electrical connection of main circuit

Screw connection

Motor drive optional

Device construction

Built-in device fixed built-in technique

Number of auxiliary contacts as change-over contact

0

Adjustment range undelayed short-circuit release

- .. -A

Suitable for DIN rail (top hat rail) mounting

With switched-off indicator

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

36kA

Adjustment range short-term delayed short-circuit release

- .. -A

Position of connection for main current circuit

Front side

DIN rail (top hat rail) mounting optional

Complete device with protection unit

Integrated earth fault protection

With under voltage release

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.