Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • SCHNEIDER

Technical specifications

Overload release current setting30 - 30A
Number of poles1
Rated voltage277 - 277V
Number of auxiliary contacts as normally open contact0
Rated permanent current Iu30A
Number of auxiliary contacts as change-over contact0
Number of auxiliary contacts as normally closed contact0
Motor drive integratedNo
Type of electrical connection of main circuitScrew connection
Position of connection for main current circuitFront side
Degree of protection (IP)IP40
Adjustment range short-term delayed short-circuit release- - -A
Complete device with protection unitYes
Device constructionBuilt-in device fixed built-in technique
With switched-off indicatorYes
Adjustment range undelayed short-circuit release300 - 300A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz36kA
Suitable for DIN rail (top hat rail) mountingNo
Type of control elementToggle
Integrated earth fault protectionNo
Motor drive optionalYes
DIN rail (top hat rail) mounting optionalYes
With under voltage releaseNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

LV438565

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • SCHNEIDER

Technical specifications

Overload release current setting

30 .. 30A

Number of poles

1

Rated voltage

277 .. 277V

Number of auxiliary contacts as normally open contact

0

Rated permanent current Iu

30A

Number of auxiliary contacts as change-over contact

0

Number of auxiliary contacts as normally closed contact

0

Motor drive integrated

Type of electrical connection of main circuit

Screw connection

Position of connection for main current circuit

Front side

Degree of protection (IP)

IP40

Adjustment range short-term delayed short-circuit release

- .. -A

Complete device with protection unit

Device construction

Built-in device fixed built-in technique

With switched-off indicator

Adjustment range undelayed short-circuit release

300 .. 300A

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

36kA

Suitable for DIN rail (top hat rail) mounting

Type of control element

Toggle

Integrated earth fault protection

Motor drive optional

DIN rail (top hat rail) mounting optional

With under voltage release

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.