Technical specifications

Height90mm
Width71.2mm
Number of digital outputs4
Depth59.5mm
Number of digital inputs8
ExpandableNo
Suitable for safety functionsNo
With time switch clockYes
With displayYes
Switching current8A
Number of analogue inputs0
Supporting protocol for LONNo
Voltage type of supply voltageAC
Number of analogue outputs0
Number of HW-interfaces industrial Ethernet0
Number of HW-interfaces RS-2321
Number of HW-interfaces RS-4220
Number of HW-interfaces RS-4850
Number of HW-interfaces parallel0
Number of HW-interfaces serial TTY0
Supporting protocol for CANNo
Number of HW-interfaces USB0
Supporting protocol for Data-HighwayNo
Supporting protocol for INTERBUSNo
Explosion safety category for dustNone
Supporting protocol for DeviceNetNo
Explosion safety category for gasNone
Number of HW-interfaces other1
With optical interfaceNo
Supporting protocol for PROFIBUSNo
Supporting protocol for other bus systemsNo
Supporting protocol for ASINo
Rail mounting possibleYes
Supporting protocol for SUCONETNo
Supporting protocol for TCP/IPNo
Supporting protocol for ModbusNo
With relay outputYes
Supporting protocol for KNXNo
RedundancyNo
Appendant operation agent (Ex ia)No
Degree of protection (IP)IP20
Supporting protocol for SERCOSNo
Expansion deviceNo
IO link masterNo
Rack-assembly possibleNo
Wall mounting/direct mountingYes
Supporting protocol for PROFINET IONo
Supporting protocol for AS-Interface Safety at WorkNo
Supporting protocol for EtherNet/IPNo
Appendant operation agent (Ex ib)No
Supporting protocol for PROFIsafeNo
Supporting protocol for DeviceNet SafetyNo
Supporting protocol for Foundation FieldbusNo
Number of interfaces PROFINET0
Basic deviceYes
Performance level according to EN ISO 13849-1None
Supporting protocol for PROFINET CBANo
Supporting protocol for INTERBUS-SafetyNo
Supply voltage AC 50 Hz24 - 24V
Radio standard Wi-Fi 802.11No
Radio standard BluetoothNo
Supporting protocol for SafetyBUS pNo
Number of HW-interfaces Wireless0
Front built-in possibleYes
Supply voltage AC 60 Hz24 - 24V
Radio standard GSMNo
SIL according to IEC 61508None
Radio standard UMTSNo
Supply voltage DC0 - 0V
Radio standard GPRSNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

SR2B121B

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Programmable logic controllers PLC
  • Logic module
  • 1 KOM
  • SCHNEIDER

Technical specifications

Height

90mm

Width

71.2mm

Number of digital outputs

4

Depth

59.5mm

Number of digital inputs

8

Expandable

Suitable for safety functions

With time switch clock

With display

Switching current

8A

Number of analogue inputs

0

Supporting protocol for LON

Voltage type of supply voltage

AC

Number of analogue outputs

0

Number of HW-interfaces industrial Ethernet

0

Number of HW-interfaces RS-232

1

Number of HW-interfaces RS-422

0

Number of HW-interfaces RS-485

0

Number of HW-interfaces parallel

0

Number of HW-interfaces serial TTY

0

Supporting protocol for CAN

Number of HW-interfaces USB

0

Supporting protocol for Data-Highway

Supporting protocol for INTERBUS

Explosion safety category for dust

None

Supporting protocol for DeviceNet

Explosion safety category for gas

None

Number of HW-interfaces other

1

With optical interface

Supporting protocol for PROFIBUS

Supporting protocol for other bus systems

Supporting protocol for ASI

Rail mounting possible

Supporting protocol for SUCONET

Supporting protocol for TCP/IP

Supporting protocol for Modbus

With relay output

Supporting protocol for KNX

Redundancy

Appendant operation agent (Ex ia)

Degree of protection (IP)

IP20

Supporting protocol for SERCOS

Expansion device

IO link master

Rack-assembly possible

Wall mounting/direct mounting

Supporting protocol for PROFINET IO

Supporting protocol for AS-Interface Safety at Work

Supporting protocol for EtherNet/IP

Appendant operation agent (Ex ib)

Supporting protocol for PROFIsafe

Supporting protocol for DeviceNet Safety

Supporting protocol for Foundation Fieldbus

Number of interfaces PROFINET

0

Basic device

Performance level according to EN ISO 13849-1

None

Supporting protocol for PROFINET CBA

Supporting protocol for INTERBUS-Safety

Supply voltage AC 50 Hz

24 .. 24V

Radio standard Wi-Fi 802.11

Radio standard Bluetooth

Supporting protocol for SafetyBUS p

Number of HW-interfaces Wireless

0

Front built-in possible

Supply voltage AC 60 Hz

24 .. 24V

Radio standard GSM

SIL according to IEC 61508

None

Radio standard UMTS

Supply voltage DC

0 .. 0V

Radio standard GPRS

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.