  • Programmable logic controllers PLC
  • Logic module
  • 1 KOM
  • SCHNEIDER

Technical specifications

Width35mm
Height90mm
Depth59.5mm
Switching current8A
With displayNo
Voltage type of supply voltageAC/DC
Number of digital inputs4
Supporting protocol for LONNo
Number of HW-interfaces RS-4220
Number of HW-interfaces RS-2320
Number of HW-interfaces industrial Ethernet0
Number of digital outputs2
Number of HW-interfaces USB0
Number of HW-interfaces serial TTY0
Number of analogue inputs0
With time switch clockNo
Number of HW-interfaces RS-4850
Suitable for safety functionsNo
Number of analogue outputs0
ExpandableNo
Supporting protocol for ASINo
Supporting protocol for CANNo
Supporting protocol for PROFIBUSNo
Supporting protocol for TCP/IPNo
With optical interfaceNo
Number of HW-interfaces other0
Number of HW-interfaces parallel0
Supporting protocol for SUCONETNo
Rail mounting possibleYes
Supporting protocol for other bus systemsNo
Supporting protocol for INTERBUSNo
Supporting protocol for DeviceNetNo
Explosion safety category for dustNone
Explosion safety category for gasNone
Appendant operation agent (Ex ib)No
Appendant operation agent (Ex ia)No
RedundancyNo
With relay outputYes
Supporting protocol for Data-HighwayNo
Supporting protocol for ModbusNo
Supporting protocol for KNXNo
Supporting protocol for INTERBUS-SafetyNo
Degree of protection (IP)IP20
Supporting protocol for SERCOSNo
Expansion deviceYes
Number of HW-interfaces Wireless0
Radio standard BluetoothNo
Number of interfaces PROFINET0
Wall mounting/direct mountingYes
Front built-in possibleYes
Rack-assembly possibleNo
Radio standard Wi-Fi 802.11No
Basic deviceYes
SIL according to IEC 61508None
Supporting protocol for SafetyBUS pNo
Radio standard UMTSNo
IO link masterNo
Supporting protocol for EtherNet/IPNo
Supporting protocol for AS-Interface Safety at WorkNo
Supporting protocol for PROFINET CBANo
Supply voltage AC 50 Hz24 - 24V
Performance level according to EN ISO 13849-1None
Supply voltage AC 60 Hz24 - 24V
Supporting protocol for Foundation FieldbusNo
Supporting protocol for PROFIsafeNo
Radio standard GPRSNo
Supporting protocol for PROFINET IONo
Supply voltage DC- - -V
Supporting protocol for DeviceNet SafetyNo
Radio standard GSMNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

SR3XT61B

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Programmable logic controllers PLC
  • Logic module
  • 1 KOM
  • SCHNEIDER

Technical specifications

Width

35mm

Height

90mm

Depth

59.5mm

Switching current

8A

With display

Voltage type of supply voltage

AC/DC

Number of digital inputs

4

Supporting protocol for LON

Number of HW-interfaces RS-422

0

Number of HW-interfaces RS-232

0

Number of HW-interfaces industrial Ethernet

0

Number of digital outputs

2

Number of HW-interfaces USB

0

Number of HW-interfaces serial TTY

0

Number of analogue inputs

0

With time switch clock

Number of HW-interfaces RS-485

0

Suitable for safety functions

Number of analogue outputs

0

Expandable

Supporting protocol for ASI

Supporting protocol for CAN

Supporting protocol for PROFIBUS

Supporting protocol for TCP/IP

With optical interface

Number of HW-interfaces other

0

Number of HW-interfaces parallel

0

Supporting protocol for SUCONET

Rail mounting possible

Supporting protocol for other bus systems

Supporting protocol for INTERBUS

Supporting protocol for DeviceNet

Explosion safety category for dust

None

Explosion safety category for gas

None

Appendant operation agent (Ex ib)

Appendant operation agent (Ex ia)

Redundancy

With relay output

Supporting protocol for Data-Highway

Supporting protocol for Modbus

Supporting protocol for KNX

Supporting protocol for INTERBUS-Safety

Degree of protection (IP)

IP20

Supporting protocol for SERCOS

Expansion device

Number of HW-interfaces Wireless

0

Radio standard Bluetooth

Number of interfaces PROFINET

0

Wall mounting/direct mounting

Front built-in possible

Rack-assembly possible

Radio standard Wi-Fi 802.11

Basic device

SIL according to IEC 61508

None

Supporting protocol for SafetyBUS p

Radio standard UMTS

IO link master

Supporting protocol for EtherNet/IP

Supporting protocol for AS-Interface Safety at Work

Supporting protocol for PROFINET CBA

Supply voltage AC 50 Hz

24 .. 24V

Performance level according to EN ISO 13849-1

None

Supply voltage AC 60 Hz

24 .. 24V

Supporting protocol for Foundation Fieldbus

Supporting protocol for PROFIsafe

Radio standard GPRS

Supporting protocol for PROFINET IO

Supply voltage DC

- .. -V

Supporting protocol for DeviceNet Safety

Radio standard GSM

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.