Aleta.hr

Details

  • Programmable logic controllers PLC
  • Fieldbus, decentr. periphery - analogue I/O module
  • 1 KOM
  • SCHNEIDER

Technical specifications

Depth70mm
Suitable for safety functionsNo
Number of analogue inputs8
Width128.3mm
Height18.4mm
Number of analogue outputs0
Voltage type of supply voltageDC
Supporting protocol for LONNo
Number of HW-interfaces RS-4220
Number of HW-interfaces other0
Supporting protocol for ASINo
Number of HW-interfaces USB0
Supporting protocol for CANNo
Number of HW-interfaces RS-2320
Supporting protocol for INTERBUSNo
Number of HW-interfaces RS-4850
Supporting protocol for TCP/IPNo
Number of HW-interfaces industrial Ethernet0
Supporting protocol for ModbusNo
Supporting protocol for KNXNo
Number of HW-interfaces serial TTY0
Number of HW-interfaces parallel0
Supporting protocol for PROFIBUSNo
Input, resistorNo
Input, voltageNo
Supporting protocol for DeviceNetNo
Supporting protocol for other bus systemsNo
Supporting protocol for SUCONETNo
Supporting protocol for Data-HighwayNo
Input, currentYes
Resolution of the analogue outputs-Bit
Input, thermocoupleNo
Input signal, configurableYes
Resolution of the analogue inputs15Bit
Appendant operation agent (Ex ib)No
Output, currentNo
Output, voltageNo
Output signal configurableNo
Degree of protection (IP)IP20
Explosion safety category for dustOther
Rail mounting possibleYes
Explosion safety category for gasATEX gas-ex-protection, Cat. 3G
Appendant operation agent (Ex ia)No
System accessoryYes
Type of electric connectionScrew connection
Input, resistance thermometerNo
Fieldbus connection over separate bus coupler possibleYes
Wall mounting/direct mountingNo
Supporting protocol for SERCOSNo
Rack-assembly possibleYes
Number of interfaces PROFINET0
Number of HW-interfaces Wireless0
Supporting protocol for INTERBUS-SafetyNo
Front built-in possibleNo
Radio standard BluetoothNo
Supporting protocol for AS-Interface Safety at WorkNo
Supporting protocol for DeviceNet SafetyNo
Supporting protocol for Foundation FieldbusNo
Supporting protocol for PROFINET CBANo
Supporting protocol for SafetyBUS pNo
Radio standard GPRSNo
Radio standard Wi-Fi 802.11No
Analogue outputs configurableNo
IO link masterNo
Supporting protocol for PROFINET IONo
Performance level according to EN ISO 13849-1None
Supply voltage DC24 - 24V
Supporting protocol for EtherNet/IPNo
Supply voltage AC 50 Hz- - -V
Supporting protocol for PROFIsafeNo
Supply voltage AC 60 Hz- - -V
Radio standard GSMNo
Radio standard UMTSNo
SIL according to IEC 61508None
Analogue inputs configurableYes
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

STBACI1400K

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Programmable logic controllers PLC
  • Fieldbus, decentr. periphery - analogue I/O module
  • 1 KOM
  • SCHNEIDER

Technical specifications

Depth

70mm

Suitable for safety functions

Number of analogue inputs

8

Width

128.3mm

Height

18.4mm

Number of analogue outputs

0

Voltage type of supply voltage

DC

Supporting protocol for LON

Number of HW-interfaces RS-422

0

Number of HW-interfaces other

0

Supporting protocol for ASI

Number of HW-interfaces USB

0

Supporting protocol for CAN

Number of HW-interfaces RS-232

0

Supporting protocol for INTERBUS

Number of HW-interfaces RS-485

0

Supporting protocol for TCP/IP

Number of HW-interfaces industrial Ethernet

0

Supporting protocol for Modbus

Supporting protocol for KNX

Number of HW-interfaces serial TTY

0

Number of HW-interfaces parallel

0

Supporting protocol for PROFIBUS

Input, resistor

Input, voltage

Supporting protocol for DeviceNet

Supporting protocol for other bus systems

Supporting protocol for SUCONET

Supporting protocol for Data-Highway

Input, current

Resolution of the analogue outputs

-Bit

Input, thermocouple

Input signal, configurable

Resolution of the analogue inputs

15Bit

Appendant operation agent (Ex ib)

Output, current

Output, voltage

Output signal configurable

Degree of protection (IP)

IP20

Explosion safety category for dust

Other

Rail mounting possible

Explosion safety category for gas

ATEX gas-ex-protection, Cat. 3G

Appendant operation agent (Ex ia)

System accessory

Type of electric connection

Screw connection

Input, resistance thermometer

Fieldbus connection over separate bus coupler possible

Wall mounting/direct mounting

Supporting protocol for SERCOS

Rack-assembly possible

Number of interfaces PROFINET

0

Number of HW-interfaces Wireless

0

Supporting protocol for INTERBUS-Safety

Front built-in possible

Radio standard Bluetooth

Supporting protocol for AS-Interface Safety at Work

Supporting protocol for DeviceNet Safety

Supporting protocol for Foundation Fieldbus

Supporting protocol for PROFINET CBA

Supporting protocol for SafetyBUS p

Radio standard GPRS

Radio standard Wi-Fi 802.11

Analogue outputs configurable

IO link master

Supporting protocol for PROFINET IO

Performance level according to EN ISO 13849-1

None

Supply voltage DC

24 .. 24V

Supporting protocol for EtherNet/IP

Supply voltage AC 50 Hz

- .. -V

Supporting protocol for PROFIsafe

Supply voltage AC 60 Hz

- .. -V

Radio standard GSM

Radio standard UMTS

SIL according to IEC 61508

None

Analogue inputs configurable