Aleta.hr

Details

  • Programmable logic controllers PLC
  • Fieldbus, decentr. periphery - digital I/O module
  • 1 KOM
  • SCHNEIDER

Technical specifications

Height18.4mm
Number of digital inputs2
Number of HW-interfaces RS-2320
Suitable for safety functionsNo
Number of HW-interfaces RS-4220
Depth65.1mm
Supporting protocol for LONNo
Width125mm
Number of HW-interfaces industrial Ethernet0
Time delay at signal exchange0.925 - 1.35ms
Voltage type of supply voltageAC/DC
Number of HW-interfaces serial TTY0
Input current at signal 12.5mA
Number of digital outputs0
Number of HW-interfaces RS-4850
With optical interfaceNo
Number of HW-interfaces USB0
Number of HW-interfaces other0
Number of HW-interfaces parallel0
Supporting protocol for CANYes
Supporting protocol for TCP/IPYes
Fieldbus connection over separate bus coupler possibleYes
Supporting protocol for ASINo
Type of digital outputNone
Supporting protocol for SUCONETNo
Supporting protocol for INTERBUSYes
Supporting protocol for Data-HighwayNo
Supporting protocol for PROFIBUSYes
Short-circuit protection, outputs availableNo
Explosion safety category for gasNone
Supporting protocol for DeviceNetYes
Explosion safety category for dustNone
Supporting protocol for other bus systemsNo
Supporting protocol for KNXNo
System accessoryYes
Supporting protocol for ModbusYes
Output current0A
Type of electric connectionScrew connection
Supporting protocol for SERCOSNo
Degree of protection (IP)IP20
Appendant operation agent (Ex ib)No
Type of voltage (input voltage)AC/DC
Appendant operation agent (Ex ia)No
Rail mounting possibleNo
Number of interfaces PROFINET0
Wall mounting/direct mountingNo
Rack-assembly possibleNo
Supporting protocol for INTERBUS-SafetyNo
Front built-in possibleNo
Number of HW-interfaces Wireless0
Supporting protocol for PROFINET CBANo
Supporting protocol for DeviceNet SafetyNo
IO link masterNo
Supporting protocol for AS-Interface Safety at WorkNo
Supporting protocol for Foundation FieldbusNo
Performance level according to EN ISO 13849-1None
Supporting protocol for EtherNet/IPYes
Radio standard Wi-Fi 802.11No
Radio standard BluetoothNo
Digital inputs configurableNo
Supply voltage AC 60 Hz115 - 115V
Supply voltage DC- - -V
Supporting protocol for SafetyBUS pNo
Supporting protocol for PROFIsafeNo
Supply voltage AC 50 Hz115 - 115V
Supporting protocol for PROFINET IONo
Permitted voltage at input-3 - 30V
Permitted voltage at output0 - 0V
Type of output voltageAC/DC
Radio standard UMTSNo
Digital outputs configurableNo
Radio standard GSMNo
SIL according to IEC 61508None
Radio standard GPRSNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

Item is no longer available for sale!

STBDAI5230K

Main Product Image

Details

  • Programmable logic controllers PLC
  • Fieldbus, decentr. periphery - digital I/O module
  • 1 KOM
  • SCHNEIDER

Technical specifications

Height

18.4mm

Number of digital inputs

2

Number of HW-interfaces RS-232

0

Suitable for safety functions

Number of HW-interfaces RS-422

0

Depth

65.1mm

Supporting protocol for LON

Width

125mm

Number of HW-interfaces industrial Ethernet

0

Time delay at signal exchange

0.925 .. 1.35ms

Voltage type of supply voltage

AC/DC

Number of HW-interfaces serial TTY

0

Input current at signal 1

2.5mA

Number of digital outputs

0

Number of HW-interfaces RS-485

0

With optical interface

Number of HW-interfaces USB

0

Number of HW-interfaces other

0

Number of HW-interfaces parallel

0

Supporting protocol for CAN

Supporting protocol for TCP/IP

Fieldbus connection over separate bus coupler possible

Supporting protocol for ASI

Type of digital output

None

Supporting protocol for SUCONET

Supporting protocol for INTERBUS

Supporting protocol for Data-Highway

Supporting protocol for PROFIBUS

Short-circuit protection, outputs available

Explosion safety category for gas

None

Supporting protocol for DeviceNet

Explosion safety category for dust

None

Supporting protocol for other bus systems

Supporting protocol for KNX

System accessory

Supporting protocol for Modbus

Output current

0A

Type of electric connection

Screw connection

Supporting protocol for SERCOS

Degree of protection (IP)

IP20

Appendant operation agent (Ex ib)

Type of voltage (input voltage)

AC/DC

Appendant operation agent (Ex ia)

Rail mounting possible

Number of interfaces PROFINET

0

Wall mounting/direct mounting

Rack-assembly possible

Supporting protocol for INTERBUS-Safety

Front built-in possible

Number of HW-interfaces Wireless

0

Supporting protocol for PROFINET CBA

Supporting protocol for DeviceNet Safety

IO link master

Supporting protocol for AS-Interface Safety at Work

Supporting protocol for Foundation Fieldbus

Performance level according to EN ISO 13849-1

None

Supporting protocol for EtherNet/IP

Radio standard Wi-Fi 802.11

Radio standard Bluetooth

Digital inputs configurable

Supply voltage AC 60 Hz

115 .. 115V

Supply voltage DC

- .. -V

Supporting protocol for SafetyBUS p

Supporting protocol for PROFIsafe

Supply voltage AC 50 Hz

115 .. 115V

Supporting protocol for PROFINET IO

Permitted voltage at input

-3 .. 30V

Permitted voltage at output

0 .. 0V

Type of output voltage

AC/DC

Radio standard UMTS

Digital outputs configurable

Radio standard GSM

SIL according to IEC 61508

None

Radio standard GPRS

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.