Details

  • Programmable logic controllers PLC
  • Fieldbus, decentr. periphery - digital I/O module
  • 1 KOM
  • SCHNEIDER

Technical specifications

Width125mm
Depth65.1mm
Input current at signal 12.5mA
Height18.4mm
Number of digital inputs0
Suitable for safety functionsNo
Time delay at signal exchange0.925 - 1.35ms
Number of digital outputs2
Voltage type of supply voltageAC/DC
Supporting protocol for LONNo
Number of HW-interfaces industrial Ethernet0
With optical interfaceNo
Number of HW-interfaces other0
Supporting protocol for KNXNo
Supporting protocol for INTERBUSYes
Number of HW-interfaces RS-4850
Number of HW-interfaces RS-4220
Type of voltage (input voltage)AC/DC
Number of HW-interfaces RS-2320
Number of HW-interfaces parallel0
Supporting protocol for ASINo
Supporting protocol for ModbusYes
Number of HW-interfaces serial TTY0
Supporting protocol for CANYes
Number of HW-interfaces USB0
Supporting protocol for PROFIBUSYes
Supporting protocol for TCP/IPYes
Supporting protocol for SUCONETNo
Short-circuit protection, outputs availableNo
Type of digital outputNone
Supporting protocol for DeviceNetYes
Supporting protocol for other bus systemsNo
Supporting protocol for Data-HighwayNo
Output current2A
System accessoryYes
Explosion safety category for dustNone
Supporting protocol for INTERBUS-SafetyNo
Explosion safety category for gasNone
Appendant operation agent (Ex ib)No
Appendant operation agent (Ex ia)No
Type of electric connectionScrew connection
Wall mounting/direct mountingNo
Radio standard BluetoothNo
Number of HW-interfaces Wireless0
Supporting protocol for SERCOSNo
Front built-in possibleNo
Rack-assembly possibleNo
Fieldbus connection over separate bus coupler possibleYes
Rail mounting possibleNo
Number of interfaces PROFINET0
Degree of protection (IP)IP20
IO link masterNo
Performance level according to EN ISO 13849-1None
Supporting protocol for Foundation FieldbusNo
Supporting protocol for EtherNet/IPYes
Radio standard Wi-Fi 802.11No
Supporting protocol for AS-Interface Safety at WorkNo
Supporting protocol for PROFINET CBANo
Supporting protocol for DeviceNet SafetyNo
Permitted voltage at input-3 - 30V
Supply voltage DC- - -V
Supporting protocol for PROFINET IONo
Supply voltage AC 50 Hz115 - 115V
Radio standard GPRSNo
Radio standard GSMNo
Radio standard UMTSNo
Supporting protocol for PROFIsafeNo
Digital outputs configurableNo
SIL according to IEC 61508None
Supply voltage AC 60 Hz115 - 115V
Permitted voltage at output74 - 132V
Digital inputs configurableNo
Supporting protocol for SafetyBUS pNo
Type of output voltageAC/DC
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

Item is no longer available for sale!

STBDAO5260K

Main Product Image

Details

  • Programmable logic controllers PLC
  • Fieldbus, decentr. periphery - digital I/O module
  • 1 KOM
  • SCHNEIDER

Technical specifications

Width

125mm

Depth

65.1mm

Input current at signal 1

2.5mA

Height

18.4mm

Number of digital inputs

0

Suitable for safety functions

Time delay at signal exchange

0.925 .. 1.35ms

Number of digital outputs

2

Voltage type of supply voltage

AC/DC

Supporting protocol for LON

Number of HW-interfaces industrial Ethernet

0

With optical interface

Number of HW-interfaces other

0

Supporting protocol for KNX

Supporting protocol for INTERBUS

Number of HW-interfaces RS-485

0

Number of HW-interfaces RS-422

0

Type of voltage (input voltage)

AC/DC

Number of HW-interfaces RS-232

0

Number of HW-interfaces parallel

0

Supporting protocol for ASI

Supporting protocol for Modbus

Number of HW-interfaces serial TTY

0

Supporting protocol for CAN

Number of HW-interfaces USB

0

Supporting protocol for PROFIBUS

Supporting protocol for TCP/IP

Supporting protocol for SUCONET

Short-circuit protection, outputs available

Type of digital output

None

Supporting protocol for DeviceNet

Supporting protocol for other bus systems

Supporting protocol for Data-Highway

Output current

2A

System accessory

Explosion safety category for dust

None

Supporting protocol for INTERBUS-Safety

Explosion safety category for gas

None

Appendant operation agent (Ex ib)

Appendant operation agent (Ex ia)

Type of electric connection

Screw connection

Wall mounting/direct mounting

Radio standard Bluetooth

Number of HW-interfaces Wireless

0

Supporting protocol for SERCOS

Front built-in possible

Rack-assembly possible

Fieldbus connection over separate bus coupler possible

Rail mounting possible

Number of interfaces PROFINET

0

Degree of protection (IP)

IP20

IO link master

Performance level according to EN ISO 13849-1

None

Supporting protocol for Foundation Fieldbus

Supporting protocol for EtherNet/IP

Radio standard Wi-Fi 802.11

Supporting protocol for AS-Interface Safety at Work

Supporting protocol for PROFINET CBA

Supporting protocol for DeviceNet Safety

Permitted voltage at input

-3 .. 30V

Supply voltage DC

- .. -V

Supporting protocol for PROFINET IO

Supply voltage AC 50 Hz

115 .. 115V

Radio standard GPRS

Radio standard GSM

Radio standard UMTS

Supporting protocol for PROFIsafe

Digital outputs configurable

SIL according to IEC 61508

None

Supply voltage AC 60 Hz

115 .. 115V

Permitted voltage at output

74 .. 132V

Digital inputs configurable

Supporting protocol for SafetyBUS p

Type of output voltage

AC/DC

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.