Aleta.hr

Details

  • Programmable logic controllers PLC
  • Fieldbus, decentr. periphery - digital I/O module
  • 1 KOM
  • SCHNEIDER

Technical specifications

Width125mm
Depth65.1mm
Input current at signal 12.5mA
Suitable for safety functionsNo
Height18.4mm
Voltage type of supply voltageAC
Number of HW-interfaces industrial Ethernet0
Number of HW-interfaces RS-4220
Number of digital inputs0
Supporting protocol for LONNo
Number of HW-interfaces RS-2320
Time delay at signal exchange0.925 - 1.35ms
Number of digital outputs2
Number of HW-interfaces other0
Number of HW-interfaces parallel0
Number of HW-interfaces serial TTY0
Type of voltage (input voltage)AC
Number of HW-interfaces RS-4850
Number of HW-interfaces USB0
Supporting protocol for TCP/IPYes
With optical interfaceNo
Supporting protocol for ASINo
Supporting protocol for PROFIBUSYes
Short-circuit protection, outputs availableNo
Supporting protocol for ModbusYes
Supporting protocol for KNXNo
Type of electric connectionScrew connection
Supporting protocol for Data-HighwayNo
Supporting protocol for SUCONETNo
Supporting protocol for DeviceNetYes
Type of digital outputNone
Supporting protocol for other bus systemsNo
Output current0A
Supporting protocol for CANYes
Supporting protocol for INTERBUSYes
Explosion safety category for dustNone
Explosion safety category for gasNone
Rail mounting possibleNo
Appendant operation agent (Ex ia)No
System accessoryYes
Fieldbus connection over separate bus coupler possibleYes
Appendant operation agent (Ex ib)No
Degree of protection (IP)IP20
IO link masterNo
Supporting protocol for INTERBUS-SafetyNo
Rack-assembly possibleNo
Number of interfaces PROFINET0
Front built-in possibleNo
Radio standard Wi-Fi 802.11No
Number of HW-interfaces Wireless0
Supporting protocol for PROFINET CBANo
Supporting protocol for DeviceNet SafetyNo
Supporting protocol for SafetyBUS pNo
Supporting protocol for Foundation FieldbusNo
Performance level according to EN ISO 13849-1None
Supporting protocol for PROFIsafeNo
Wall mounting/direct mountingNo
Supporting protocol for EtherNet/IPYes
Supporting protocol for PROFINET IONo
Supporting protocol for AS-Interface Safety at WorkNo
Radio standard BluetoothNo
Supporting protocol for SERCOSNo
Supply voltage AC 50 Hz115 - 230V
Supply voltage AC 60 Hz115 - 230V
Supply voltage DC- - -V
Permitted voltage at input-3 - 30V
Permitted voltage at output0 - 0V
Type of output voltageAC
Digital inputs configurableNo
Radio standard GSMNo
Digital outputs configurableNo
Radio standard GPRSNo
SIL according to IEC 61508None
Radio standard UMTSNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

Item is no longer available for sale!

STBDAO8210K

Main Product Image

Details

  • Programmable logic controllers PLC
  • Fieldbus, decentr. periphery - digital I/O module
  • 1 KOM
  • SCHNEIDER

Technical specifications

Width

125mm

Depth

65.1mm

Input current at signal 1

2.5mA

Suitable for safety functions

Height

18.4mm

Voltage type of supply voltage

AC

Number of HW-interfaces industrial Ethernet

0

Number of HW-interfaces RS-422

0

Number of digital inputs

0

Supporting protocol for LON

Number of HW-interfaces RS-232

0

Time delay at signal exchange

0.925 .. 1.35ms

Number of digital outputs

2

Number of HW-interfaces other

0

Number of HW-interfaces parallel

0

Number of HW-interfaces serial TTY

0

Type of voltage (input voltage)

AC

Number of HW-interfaces RS-485

0

Number of HW-interfaces USB

0

Supporting protocol for TCP/IP

With optical interface

Supporting protocol for ASI

Supporting protocol for PROFIBUS

Short-circuit protection, outputs available

Supporting protocol for Modbus

Supporting protocol for KNX

Type of electric connection

Screw connection

Supporting protocol for Data-Highway

Supporting protocol for SUCONET

Supporting protocol for DeviceNet

Type of digital output

None

Supporting protocol for other bus systems

Output current

0A

Supporting protocol for CAN

Supporting protocol for INTERBUS

Explosion safety category for dust

None

Explosion safety category for gas

None

Rail mounting possible

Appendant operation agent (Ex ia)

System accessory

Fieldbus connection over separate bus coupler possible

Appendant operation agent (Ex ib)

Degree of protection (IP)

IP20

IO link master

Supporting protocol for INTERBUS-Safety

Rack-assembly possible

Number of interfaces PROFINET

0

Front built-in possible

Radio standard Wi-Fi 802.11

Number of HW-interfaces Wireless

0

Supporting protocol for PROFINET CBA

Supporting protocol for DeviceNet Safety

Supporting protocol for SafetyBUS p

Supporting protocol for Foundation Fieldbus

Performance level according to EN ISO 13849-1

None

Supporting protocol for PROFIsafe

Wall mounting/direct mounting

Supporting protocol for EtherNet/IP

Supporting protocol for PROFINET IO

Supporting protocol for AS-Interface Safety at Work

Radio standard Bluetooth

Supporting protocol for SERCOS

Supply voltage AC 50 Hz

115 .. 230V

Supply voltage AC 60 Hz

115 .. 230V

Supply voltage DC

- .. -V

Permitted voltage at input

-3 .. 30V

Permitted voltage at output

0 .. 0V

Type of output voltage

AC

Digital inputs configurable

Radio standard GSM

Digital outputs configurable

Radio standard GPRS

SIL according to IEC 61508

None

Radio standard UMTS

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.