Details

  • Programmable logic controllers PLC
  • Fieldbus, decentr. periphery - digital I/O module
  • 1 KOM
  • SCHNEIDER

Technical specifications

Depth65.1mm
Input current at signal 12.5mA
Height18.4mm
Width125mm
Number of HW-interfaces industrial Ethernet0
Time delay at signal exchange0.925 - 1.35ms
Supporting protocol for LONNo
Suitable for safety functionsNo
Number of HW-interfaces RS-4220
Number of HW-interfaces parallel0
Number of HW-interfaces RS-4850
Number of HW-interfaces serial TTY0
Number of HW-interfaces USB0
Number of HW-interfaces RS-2320
Number of HW-interfaces other0
Supporting protocol for ASINo
Supporting protocol for CANYes
Supporting protocol for TCP/IPYes
Supporting protocol for PROFIBUSYes
Type of voltage (input voltage)AC/DC
Supporting protocol for ModbusYes
With optical interfaceNo
Supporting protocol for INTERBUSYes
Supporting protocol for KNXNo
Supporting protocol for other bus systemsNo
Appendant operation agent (Ex ib)No
Short-circuit protection, outputs availableNo
Explosion safety category for gasNone
Output current0A
Supporting protocol for SUCONETNo
Rail mounting possibleNo
Fieldbus connection over separate bus coupler possibleYes
Type of digital outputNone
Type of electric connectionScrew connection
Supporting protocol for DeviceNetYes
System accessoryYes
Supporting protocol for Data-HighwayNo
Explosion safety category for dustNone
Appendant operation agent (Ex ia)No
Supporting protocol for SERCOSNo
Wall mounting/direct mountingNo
Supporting protocol for INTERBUS-SafetyNo
Supporting protocol for Foundation FieldbusNo
Supporting protocol for DeviceNet SafetyNo
Supporting protocol for PROFINET CBANo
Permitted voltage at output0 - 0V
Rack-assembly possibleNo
Radio standard Wi-Fi 802.11No
Permitted voltage at input-3 - 30V
Front built-in possibleNo
Number of interfaces PROFINET0
Supporting protocol for PROFIsafeNo
Supporting protocol for PROFINET IONo
Radio standard BluetoothNo
Number of HW-interfaces Wireless0
Performance level according to EN ISO 13849-1None
Supporting protocol for SafetyBUS pNo
Type of output voltageAC/DC
IO link masterNo
Supporting protocol for AS-Interface Safety at WorkNo
Supply voltage AC 50 Hz- - -V
Supply voltage AC 60 Hz- - -V
Supply voltage DC24 - 24V
Supporting protocol for EtherNet/IPYes
Radio standard GPRSNo
Digital inputs configurableNo
Radio standard UMTSNo
Digital outputs configurableNo
Radio standard GSMNo
SIL according to IEC 61508None
Number of digital inputs4
Number of digital outputs0
Voltage type of supply voltageAC/DC
Degree of protection (IP)IP20
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user