Aleta.hr

Details

  • Programmable logic controllers PLC
  • Fieldbus, decentr. periphery - digital I/O module
  • 1 KOM
  • SCHNEIDER

Technical specifications

Height18.4mm
Number of digital inputs6
Suitable for safety functionsNo
Width125mm
Number of digital outputs0
Depth65.1mm
Input current at signal 12mA
Number of HW-interfaces RS-2320
Time delay at signal exchange1.21 - 1.74ms
Supporting protocol for LONNo
Number of HW-interfaces RS-4220
Number of HW-interfaces RS-4850
Number of HW-interfaces serial TTY0
Voltage type of supply voltageDC
Number of HW-interfaces industrial Ethernet0
Number of HW-interfaces USB0
Number of HW-interfaces other0
Type of voltage (input voltage)DC
With optical interfaceNo
Supporting protocol for KNXNo
Supporting protocol for ModbusYes
Supporting protocol for TCP/IPYes
Supporting protocol for other bus systemsNo
Supporting protocol for PROFIBUSYes
Number of HW-interfaces parallel0
Supporting protocol for ASINo
Supporting protocol for INTERBUSYes
Output current0A
Supporting protocol for CANYes
Supporting protocol for Data-HighwayNo
Supporting protocol for SUCONETNo
Supporting protocol for DeviceNetYes
System accessoryYes
Type of digital outputNone
Rail mounting possibleNo
Explosion safety category for dustNone
Type of electric connectionScrew connection
Fieldbus connection over separate bus coupler possibleYes
Short-circuit protection, outputs availableNo
Explosion safety category for gasNone
Appendant operation agent (Ex ia)No
Number of HW-interfaces Wireless0
Supporting protocol for SERCOSNo
Appendant operation agent (Ex ib)No
Front built-in possibleNo
Supporting protocol for EtherNet/IPYes
Degree of protection (IP)IP20
Supporting protocol for Foundation FieldbusNo
Performance level according to EN ISO 13849-1None
Supporting protocol for INTERBUS-SafetyNo
Number of interfaces PROFINET0
IO link masterNo
Supporting protocol for AS-Interface Safety at WorkNo
Supporting protocol for DeviceNet SafetyNo
Supporting protocol for PROFIsafeNo
Supporting protocol for PROFINET IONo
Radio standard BluetoothNo
Rack-assembly possibleYes
Wall mounting/direct mountingNo
Supporting protocol for PROFINET CBANo
Radio standard Wi-Fi 802.11No
Supply voltage AC 60 Hz- - -V
Supply voltage DC24 - 24V
Supply voltage AC 50 Hz- - -V
Supporting protocol for SafetyBUS pNo
Digital inputs configurableNo
Type of output voltageDC
Permitted voltage at input-3 - 30V
Digital outputs configurableNo
Radio standard UMTSNo
Radio standard GPRSNo
Permitted voltage at output0 - 0V
Radio standard GSMNo
SIL according to IEC 61508None
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

STBDDI3610K | Modul Dig. 24 VDC in 6PT Sink 2WIRE 1 MS

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Programmable logic controllers PLC
  • Fieldbus, decentr. periphery - digital I/O module
  • 1 KOM
  • SCHNEIDER

Technical specifications

Height

18.4mm

Number of digital inputs

6

Suitable for safety functions

Width

125mm

Number of digital outputs

0

Depth

65.1mm

Input current at signal 1

2mA

Number of HW-interfaces RS-232

0

Time delay at signal exchange

1.21 .. 1.74ms

Supporting protocol for LON

Number of HW-interfaces RS-422

0

Number of HW-interfaces RS-485

0

Number of HW-interfaces serial TTY

0

Voltage type of supply voltage

DC

Number of HW-interfaces industrial Ethernet

0

Number of HW-interfaces USB

0

Number of HW-interfaces other

0

Type of voltage (input voltage)

DC

With optical interface

Supporting protocol for KNX

Supporting protocol for Modbus

Supporting protocol for TCP/IP

Supporting protocol for other bus systems

Supporting protocol for PROFIBUS

Number of HW-interfaces parallel

0

Supporting protocol for ASI

Supporting protocol for INTERBUS

Output current

0A

Supporting protocol for CAN

Supporting protocol for Data-Highway

Supporting protocol for SUCONET

Supporting protocol for DeviceNet

System accessory

Type of digital output

None

Rail mounting possible

Explosion safety category for dust

None

Type of electric connection

Screw connection

Fieldbus connection over separate bus coupler possible

Short-circuit protection, outputs available

Explosion safety category for gas

None

Appendant operation agent (Ex ia)

Number of HW-interfaces Wireless

0

Supporting protocol for SERCOS

Appendant operation agent (Ex ib)

Front built-in possible

Supporting protocol for EtherNet/IP

Degree of protection (IP)

IP20

Supporting protocol for Foundation Fieldbus

Performance level according to EN ISO 13849-1

None

Supporting protocol for INTERBUS-Safety

Number of interfaces PROFINET

0

IO link master

Supporting protocol for AS-Interface Safety at Work

Supporting protocol for DeviceNet Safety

Supporting protocol for PROFIsafe

Supporting protocol for PROFINET IO

Radio standard Bluetooth

Rack-assembly possible

Wall mounting/direct mounting

Supporting protocol for PROFINET CBA

Radio standard Wi-Fi 802.11

Supply voltage AC 60 Hz

- .. -V

Supply voltage DC

24 .. 24V

Supply voltage AC 50 Hz

- .. -V

Supporting protocol for SafetyBUS p

Digital inputs configurable

Type of output voltage

DC

Permitted voltage at input

-3 .. 30V

Digital outputs configurable

Radio standard UMTS

Radio standard GPRS

Permitted voltage at output

0 .. 0V

Radio standard GSM

SIL according to IEC 61508

None

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.