Aleta.hr

Details

  • Programmable logic controllers PLC
  • Fieldbus, decentr. periphery - digital I/O module
  • 1 KOM
  • SCHNEIDER

Technical specifications

Supply voltage AC 50 Hz- - -V
Supply voltage AC 60 Hz- - -V
Output current0A
Permitted voltage at output0 - 0V
Digital inputs configurableNo
Supply voltage DC24 - 24V
Number of digital inputs6
Number of digital outputs0
Digital outputs configurableNo
Voltage type of supply voltageAC/DC
Input current at signal 14.5mA
Type of voltage (input voltage)AC/DC
Permitted voltage at input-3 - 30V
Number of HW-interfaces industrial Ethernet0
Short-circuit protection, outputs availableNo
Number of HW-interfaces RS-4850
Number of HW-interfaces other0
Number of HW-interfaces RS-4220
Type of digital outputNone
Number of HW-interfaces RS-2320
Number of interfaces PROFINET0
Number of HW-interfaces serial TTY0
Number of HW-interfaces USB0
Type of output voltageAC/DC
Number of HW-interfaces Wireless0
Supporting protocol for TCP/IPNo
With optical interfaceNo
Supporting protocol for CANNo
Supporting protocol for ModbusNo
Supporting protocol for DeviceNetNo
Supporting protocol for ASINo
Supporting protocol for PROFIBUSNo
Supporting protocol for PROFINET IONo
Supporting protocol for INTERBUSNo
Supporting protocol for KNXNo
Supporting protocol for Data-HighwayNo
Supporting protocol for EtherNet/IPNo
Supporting protocol for PROFINET CBANo
Supporting protocol for Foundation FieldbusNo
Number of HW-interfaces parallel0
Supporting protocol for LONNo
Supporting protocol for SUCONETNo
Supporting protocol for SERCOSNo
IO link masterNo
System accessoryYes
Degree of protection (IP)IP20
Type of electric connectionScrew-/spring clamp connection
Fieldbus connection over separate bus coupler possibleYes
Rail mounting possibleNo
Wall mounting/direct mountingNo
Front built-in possibleNo
Time delay at signal exchange5.25 - 5.75ms
Suitable for safety functionsNo
Rack-assembly possibleYes
SIL according to IEC 61508None
Appendant operation agent (Ex ia)No
Performance level according to EN ISO 13849-1None
Appendant operation agent (Ex ib)No
Explosion safety category for gasNone
Explosion safety category for dustNone
Height18.4mm
Width125mm
Depth65.1mm
Radio standard BluetoothNo
Supporting protocol for DeviceNet SafetyNo
Supporting protocol for PROFIsafeNo
Supporting protocol for SafetyBUS pNo
Radio standard GSMNo
Radio standard UMTSNo
Radio standard Wi-Fi 802.11No
Supporting protocol for other bus systemsNo
Supporting protocol for AS-Interface Safety at WorkNo
Radio standard GPRSNo
Supporting protocol for INTERBUS-SafetyNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

STBDDI3615K

Main Product Image

Details

  • Programmable logic controllers PLC
  • Fieldbus, decentr. periphery - digital I/O module
  • 1 KOM
  • SCHNEIDER

Technical specifications

Supply voltage AC 50 Hz

- .. -V

Supply voltage AC 60 Hz

- .. -V

Output current

0A

Permitted voltage at output

0 .. 0V

Digital inputs configurable

Supply voltage DC

24 .. 24V

Number of digital inputs

6

Number of digital outputs

0

Digital outputs configurable

Voltage type of supply voltage

AC/DC

Input current at signal 1

4.5mA

Type of voltage (input voltage)

AC/DC

Permitted voltage at input

-3 .. 30V

Number of HW-interfaces industrial Ethernet

0

Short-circuit protection, outputs available

Number of HW-interfaces RS-485

0

Number of HW-interfaces other

0

Number of HW-interfaces RS-422

0

Type of digital output

None

Number of HW-interfaces RS-232

0

Number of interfaces PROFINET

0

Number of HW-interfaces serial TTY

0

Number of HW-interfaces USB

0

Type of output voltage

AC/DC

Number of HW-interfaces Wireless

0

Supporting protocol for TCP/IP

With optical interface

Supporting protocol for CAN

Supporting protocol for Modbus

Supporting protocol for DeviceNet

Supporting protocol for ASI

Supporting protocol for PROFIBUS

Supporting protocol for PROFINET IO

Supporting protocol for INTERBUS

Supporting protocol for KNX

Supporting protocol for Data-Highway

Supporting protocol for EtherNet/IP

Supporting protocol for PROFINET CBA

Supporting protocol for Foundation Fieldbus

Number of HW-interfaces parallel

0

Supporting protocol for LON

Supporting protocol for SUCONET

Supporting protocol for SERCOS

IO link master

System accessory

Degree of protection (IP)

IP20

Type of electric connection

Screw-/spring clamp connection

Fieldbus connection over separate bus coupler possible

Rail mounting possible

Wall mounting/direct mounting

Front built-in possible

Time delay at signal exchange

5.25 .. 5.75ms

Suitable for safety functions

Rack-assembly possible

SIL according to IEC 61508

None

Appendant operation agent (Ex ia)

Performance level according to EN ISO 13849-1

None

Appendant operation agent (Ex ib)

Explosion safety category for gas

None

Explosion safety category for dust

None

Height

18.4mm

Width

125mm

Depth

65.1mm

Radio standard Bluetooth

Supporting protocol for DeviceNet Safety

Supporting protocol for PROFIsafe

Supporting protocol for SafetyBUS p

Radio standard GSM

Radio standard UMTS

Radio standard Wi-Fi 802.11

Supporting protocol for other bus systems

Supporting protocol for AS-Interface Safety at Work

Radio standard GPRS

Supporting protocol for INTERBUS-Safety

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.